» Articles » PMID: 30334789

Automatic Needle Segmentation and Localization in MRI With 3-D Convolutional Neural Networks: Application to MRI-Targeted Prostate Biopsy

Overview
Date 2018 Oct 19
PMID 30334789
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Image guidance improves tissue sampling during biopsy by allowing the physician to visualize the tip and trajectory of the biopsy needle relative to the target in MRI, CT, ultrasound, or other relevant imagery. This paper reports a system for fast automatic needle tip and trajectory localization and visualization in MRI that has been developed and tested in the context of an active clinical research program in prostate biopsy. To the best of our knowledge, this is the first reported system for this clinical application and also the first reported system that leverages deep neural networks for segmentation and localization of needles in MRI across biomedical applications. Needle tip and trajectory were annotated on 583 T2-weighted intra-procedural MRI scans acquired after needle insertion for 71 patients who underwent transperineal MRI-targeted biopsy procedure at our institution. The images were divided into two independent training-validation and test sets at the patient level. A deep 3-D fully convolutional neural network model was developed, trained, and deployed on these samples. The accuracy of the proposed method, as tested on previously unseen data, was 2.80-mm average in needle tip detection and 0.98° in needle trajectory angle. An observer study was designed in which independent annotations by a second observer, blinded to the original observer, were compared with the output of the proposed method. The resultant error was comparable to the measured inter-observer concordance, reinforcing the clinical acceptability of the proposed method. The proposed system has the potential for deployment in clinical routine.

Citing Articles

Artificial intelligence in interventional radiology: state of the art.

Glielmo P, Fusco S, Gitto S, Zantonelli G, Albano D, Messina C Eur Radiol Exp. 2024; 8(1):62.

PMID: 38693468 PMC: 11063019. DOI: 10.1186/s41747-024-00452-2.


Deep learning-based automatic pipeline for 3D needle localization on intra-procedural 3D MRI.

Zhou W, Li X, Zabihollahy F, Lu D, Wu H Int J Comput Assist Radiol Surg. 2024; 19(11):2227-2237.

PMID: 38520646 PMC: 11541278. DOI: 10.1007/s11548-024-03077-3.


Two-stage generative adversarial networks for metal artifact reduction and visualization in ablation therapy of liver tumors.

Liang D, Zhang S, Zhao Z, Wang G, Sun J, Zhao J Int J Comput Assist Radiol Surg. 2023; 18(11):1991-2000.

PMID: 37391537 DOI: 10.1007/s11548-023-02986-z.


Simultaneous Online Registration-Independent Stiffness Identification and Tip Localization of Surgical Instruments in Robot-assisted Eye Surgery.

Ebrahimi A, Sefati S, Gehlbach P, Taylor R, Iordachita I IEEE Trans Robot. 2023; 39(2):1373-1387.

PMID: 37377922 PMC: 10292740. DOI: 10.1109/tro.2022.3201393.


AI-Based Isotherm Prediction for Focal Cryoablation of Prostate Cancer.

Moreira P, Tuncali K, Tempany C, Tokuda J Acad Radiol. 2023; 30 Suppl 1:S14-S20.

PMID: 37236896 PMC: 10524864. DOI: 10.1016/j.acra.2023.04.016.


References
1.
Ghafoorian M, Karssemeijer N, Heskes T, Bergkamp M, Wissink J, Obels J . Deep multi-scale location-aware 3D convolutional neural networks for automated detection of lacunes of presumed vascular origin. Neuroimage Clin. 2017; 14:391-399. PMC: 5322213. DOI: 10.1016/j.nicl.2017.01.033. View

2.
Tilak G, Tuncali K, Song S, Tokuda J, Olubiyi O, Fennessy F . 3T MR-guided in-bore transperineal prostate biopsy: A comparison of robotic and manual needle-guidance templates. J Magn Reson Imaging. 2014; 42(1):63-71. PMC: 4376663. DOI: 10.1002/jmri.24770. View

3.
Hao X, Zygmunt K, Whitaker R, Fletcher P . Improved segmentation of white matter tracts with adaptive Riemannian metrics. Med Image Anal. 2013; 18(1):161-75. PMC: 3898892. DOI: 10.1016/j.media.2013.10.007. View

4.
Hrinivich W, Hoover D, Surry K, Edirisinghe C, Montreuil J, DSouza D . Simultaneous automatic segmentation of multiple needles using 3D ultrasound for high-dose-rate prostate brachytherapy. Med Phys. 2017; 44(4):1234-1245. DOI: 10.1002/mp.12148. View

5.
Song S, Cho N, Iordachita I, Guion P, Fichtinger G, Kaushal A . Biopsy needle artifact localization in MRI-guided robotic transrectal prostate intervention. IEEE Trans Biomed Eng. 2012; 59(7):1902-11. PMC: 3675798. DOI: 10.1109/TBME.2012.2192118. View