» Articles » PMID: 29674632

Pushing the Resolution Limit by Correcting the Ewald Sphere Effect in Single-particle Cryo-EM Reconstructions

Overview
Journal Nat Commun
Specialty Biology
Date 2018 Apr 21
PMID 29674632
Citations 57
Authors
Affiliations
Soon will be listed here.
Abstract

The Ewald sphere effect is generally neglected when using the Central Projection Theorem for cryo electron microscopy single-particle reconstructions. This can reduce the resolution of a reconstruction. Here we estimate the attainable resolution and report a "block-based" reconstruction method for extending the resolution limit. We find the Ewald sphere effect limits the resolution of large objects, especially large viruses. After processing two real datasets of large viruses, we show that our procedure can extend the resolution for both datasets and can accommodate the flexibility associated with large protein complexes.

Citing Articles

Structure of the T=13 capsid of infectious pancreatic necrosis virus (IPNV)-a salmonid birnavirus.

Munke A, Ahmed Abdelrahim Gamil A, Mikalsen A, Wang H, Evensen O, Okamoto K J Virol. 2025; 99(2):e0145424.

PMID: 39817769 PMC: 11853034. DOI: 10.1128/jvi.01454-24.


Molecular basis for shifted receptor recognition by an encephalitic arbovirus.

Fan X, Li W, Oros J, Plung J, Plante J, Basu H bioRxiv. 2025; .

PMID: 39803583 PMC: 11722376. DOI: 10.1101/2025.01.01.631009.


Conventional Electron Microscopy, Cryogenic Electron Microscopy, and Cryogenic Electron Tomography of Viruses.

Caston J, Luque D Subcell Biochem. 2024; 105:81-134.

PMID: 39738945 DOI: 10.1007/978-3-031-65187-8_3.


Validation of 3D cryoEM single particle reconstruction correctness and handedness with Ewald's sphere correction.

Bromberg R, Guo Y, Borek D, Otwinowski Z bioRxiv. 2024; .

PMID: 39257812 PMC: 11383999. DOI: 10.1101/2024.08.29.610390.


Subnanometer structure of medusavirus capsid during maturation using cryo-electron microscopy.

Watanabe R, Song C, Takemura M, Murata K J Virol. 2024; 98(9):e0043624.

PMID: 39194243 PMC: 11406985. DOI: 10.1128/jvi.00436-24.


References
1.
Rohou A, Grigorieff N . CTFFIND4: Fast and accurate defocus estimation from electron micrographs. J Struct Biol. 2015; 192(2):216-21. PMC: 6760662. DOI: 10.1016/j.jsb.2015.08.008. View

2.
Kazantsev I, Klukowska J, Herman G, Cernetic L . Fully three-dimensional defocus-gradient corrected backprojection in cryoelectron microscopy. Ultramicroscopy. 2010; 110(9):1128-42. PMC: 2912958. DOI: 10.1016/j.ultramic.2010.04.002. View

3.
Grigorieff N . Frealign: An Exploratory Tool for Single-Particle Cryo-EM. Methods Enzymol. 2016; 579:191-226. PMC: 6760665. DOI: 10.1016/bs.mie.2016.04.013. View

4.
Rosenthal P, Henderson R . Optimal determination of particle orientation, absolute hand, and contrast loss in single-particle electron cryomicroscopy. J Mol Biol. 2003; 333(4):721-45. DOI: 10.1016/j.jmb.2003.07.013. View

5.
Guo F, Jiang W . Single particle cryo-electron microscopy and 3-D reconstruction of viruses. Methods Mol Biol. 2013; 1117:401-43. PMC: 4020923. DOI: 10.1007/978-1-62703-776-1_19. View