Abstract

Sensitive and specific detection of pathogens via nucleic acid amplification is currently constrained to laboratory settings and portable equipment with costly fluorescent detectors. Nucleic acid-detecting lateral flow immunoassay strips (LFIAs) offer a low-cost visual transduction strategy at points of need. Unfortunately, these LFIAs frequently detect amplification byproducts that can yield spurious results which can only be deciphered through statistical analysis. We integrated customizable strand displacement probes into standard loop mediated isothermal amplification (LAMP) assays to prevent byproduct capture on commercial LFIAs. We find that combining strand displacement with LAMP (SD-LAMP) yields LFIA test band intensities that can be unequivocally interpreted by human subjects without additional instrumentation, thereby alleviating the need for a portable reader's analysis. Using SD-LAMP, we capture target amplicons on commercially available LFIAs from as few as 3.5 Vibrio cholerae and 2 750 Escherichia coli bacteria without false positive or false negative interpretation. Moreover, we demonstrate that LFIA capture of SD-LAMP products remain specific even in the presence of complex sample matrixes, providing a significant step toward reliable instrument-free pathogen detection outside of laboratories.

Citing Articles

Compact multiplex PCR device for HIV-1 and HIV-2 viral load determination from finger-prick whole blood in resource-limited settings.

Liu T, Politza A, Ahamed M, Kshirsagar A, Zhu Y, Guan W Biosens Bioelectron. 2024; 271:116997.

PMID: 39637742 PMC: 11701890. DOI: 10.1016/j.bios.2024.116997.


Au@Pt nanoparticles-based signal-enhanced lateral flow immunoassay for ultrasensitive naked-eye detection of SARS-CoV-2.

Li X, Li H, Zhu J, Yu D, Abulaiti T, Zeng J Mikrochim Acta. 2024; 191(11):657.

PMID: 39382589 DOI: 10.1007/s00604-024-06697-3.


Biochemically Programmable Isothermal PCR.

Kim M, Ravisankar V, Hassan Y, Ugaz V Adv Sci (Weinh). 2024; 11(41):e2404688.

PMID: 39269276 PMC: 11538674. DOI: 10.1002/advs.202404688.


Direct TAMRA-dUTP labeling of M. tuberculosis genes using loop-mediated isothermal amplification (LAMP).

Altattan B, Ullrich J, Mattig E, Poppe A, Martins R, Bier F Sci Rep. 2024; 14(1):5611.

PMID: 38454089 PMC: 10920756. DOI: 10.1038/s41598-024-55289-x.


Compact Point-of-Care Device for Self-Administered HIV Viral Load Tests from Whole Blood.

Liu T, Politza A, Kshirsagar A, Zhu Y, Guan W ACS Sens. 2023; 8(12):4716-4727.

PMID: 38011515 PMC: 11222019. DOI: 10.1021/acssensors.3c01819.


References
1.
Singleton J, Osborn J, Lillis L, Hawkins K, Guelig D, Price W . Electricity-free amplification and detection for molecular point-of-care diagnosis of HIV-1. PLoS One. 2014; 9(11):e113693. PMC: 4245218. DOI: 10.1371/journal.pone.0113693. View

2.
Alam M, Weppelmann T, Weber C, Johnson J, Rashid M, Birch C . Monitoring water sources for environmental reservoirs of toxigenic Vibrio cholerae O1, Haiti. Emerg Infect Dis. 2014; 20(3):356-63. PMC: 3944837. DOI: 10.3201/eid2003.131293. View

3.
Modak S, Barber C, Geva E, Abrams W, Malamud D, Ongagna Y . Rapid Point-of-Care Isothermal Amplification Assay for the Detection of Malaria without Nucleic Acid Purification. Infect Dis (Auckl). 2016; 9:1-9. PMC: 4721682. DOI: 10.4137/IDRT.S32162. View

4.
Niemz A, Ferguson T, Boyle D . Point-of-care nucleic acid testing for infectious diseases. Trends Biotechnol. 2011; 29(5):240-50. PMC: 3746968. DOI: 10.1016/j.tibtech.2011.01.007. View

5.
Srinivas N, Ouldridge T, Sulc P, Schaeffer J, Yurke B, Louis A . On the biophysics and kinetics of toehold-mediated DNA strand displacement. Nucleic Acids Res. 2013; 41(22):10641-58. PMC: 3905871. DOI: 10.1093/nar/gkt801. View