» Articles » PMID: 21276085

Robustness of a Loop-mediated Isothermal Amplification Reaction for Diagnostic Applications

Overview
Date 2011 Feb 1
PMID 21276085
Citations 191
Authors
Affiliations
Soon will be listed here.
Abstract

We evaluated the robustness of loop-mediated isothermal amplification (LAMP) of DNA for bacterial diagnostic applications. Salmonella enterica serovar Typhi was used as the target organism and compared with a real-time quantitative PCR (qPCR) for testing assay performance and reproducibly, as well as the impact of pH and temperature stability. This isothermal amplification method appeared to be particularly robust across 2 pH units (7.3-9.3) and temperature values (57-67 °C). The detection limit was comparable to that observed using optimized home-brew qPCR assays. The specificity of the amplification reaction remained high even at temperatures markedly different from the optimal one. Exposing reagents to the ambient temperature during the preparation of the reaction mixture as well as prolonging times for preparing the amplification reaction did not yield false-positive results. LAMP remained sensitive and specific despite the addition of untreated biological fluids such as stool or urine that commonly inhibit PCR amplification. Whereas the detection of microorganisms from whole blood or a blood-culture medium typically requires extensive sample purification and removal of inhibitors, LAMP amplification remained more sensitive than conventional qPCR when omitting such preparatory steps. Our results demonstrate that LAMP is not only easy to use, but is also a very robust, innovative and powerful molecular diagnostic method for both industrialized and developing countries.

Citing Articles

Development and validation of a LAMP-based method for rapid and reliable detection of , the causal agent of sugarcane leaf scald.

Chakraborty M, Bhuiyan S, Strachan S, Shiddiky M, Nguyen N, Ford R Front Microbiol. 2025; 16:1537812.

PMID: 39949620 PMC: 11821956. DOI: 10.3389/fmicb.2025.1537812.


Next step towards point-of-care molecular diagnosis of female genital schistosomiasis (FGS): evaluation of an instrument-free LAMP procedure.

van Bergen K, Brienen E, Randrianasolo B, Ramarokoto C, Leutscher P, Kjetland E Front Parasitol. 2025; 3():1297310.

PMID: 39817178 PMC: 11731957. DOI: 10.3389/fpara.2024.1297310.


LAMP Reaction in Plant Disease Surveillance: Applications, Challenges, and Future Perspectives.

Aglietti C, Benigno A, Cacciola S, Moricca S Life (Basel). 2025; 14(12.

PMID: 39768257 PMC: 11678381. DOI: 10.3390/life14121549.


Loop-mediated isothermal amplification assays for the detection of antimicrobial resistance elements in Vibrio cholera.

Negron D, Trivedi S, Tolli N, Ashford D, Melton G, Guertin S BMC Bioinformatics. 2024; 25(1):384.

PMID: 39695927 PMC: 11657800. DOI: 10.1186/s12859-024-06001-3.


A handheld HIV detection platform using paper-based sample preparation and real-time isothermal amplification.

Adedokun G, Sidhu G, Alipanah M, Wang G, Fan Z Microsyst Nanoeng. 2024; 10(1):181.

PMID: 39613739 PMC: 11607462. DOI: 10.1038/s41378-024-00822-1.