» Articles » PMID: 29659978

Consideration of the Usefulness of a Size-specific Dose Estimate in Pediatric CT Examination

Overview
Journal J Radiat Res
Date 2018 Apr 17
PMID 29659978
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Computed tomography (CT) has recently been utilized in various medical settings, and technological advances have resulted in its widespread use. However, medical radiation exposure associated with CT scans accounts for the largest share of examinations using radiation; thus, it is important to understand the organ dose and effective dose in detail. The CT dose index and dose-length product are used to evaluate the organ dose. However, evaluations using these indicators fail to consider the age and body type of patients. In this study, we evaluated the effective dose based on the CT examination data of 753 patients examined at our hospital using the size-specific dose estimate (SSDE) method, which can calculate the exposure dose with consideration of the physique of a patient. The results showed a large correlation between the SSDE conversion factor and physique, with a larger exposure dose in patients with a small physique when a single scan is considered. Especially for children, the SSDE conversion factor was found to be 2 or more. In addition, the patient exposed to the largest dose in this study was a 10-year-old, who received 40.4 mSv (five series/examination). In the future, for estimating exposure using the SSDE method and in cohort studies, the diagnostic reference level of SSDE should be determined and a low-exposure imaging protocol should be developed to predict the risk of CT exposure and to maintain the quality of diagnosis with better radiation protection of patients.

Citing Articles

Introducing fitting models for estimating age-specific dose and effective dose in paediatric patients undergoing head, chest and abdomen-pelvis imaging protocols: a patient study.

Deevband M, Mohammadi H, Salimi Y, Mostaar A, Deravi N, Fathi M J Med Radiat Sci. 2024; 71(2):251-260.

PMID: 38454637 PMC: 11177019. DOI: 10.1002/jmrs.772.


Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT.

Rajaraman V, Ponnusamy M, Halanaik D Asia Ocean J Nucl Med Biol. 2020; 8(1):58-63.

PMID: 32064284 PMC: 6994783. DOI: 10.22038/aojnmb.2019.40863.1276.


Radiation doses with various body weights of phantoms in brain 128-slice MDCT examination.

Lin H, Lai T, Tseng H, Wang C, Tseng Y, Chen C J Radiat Res. 2019; 60(4):466-475.

PMID: 31197311 PMC: 6640898. DOI: 10.1093/jrr/rrz029.

References
1.
Turner A, Zhang D, Kim H, DeMarco J, Cagnon C, Angel E . A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations. Med Phys. 2009; 36(6):2154-64. PMC: 2754941. DOI: 10.1118/1.3117683. View

2.
Huda W, Tipnis S . Doses metrics and patient age in CT. Radiat Prot Dosimetry. 2015; 168(3):374-80. DOI: 10.1093/rpd/ncv310. View

3.
Kumamaru K, Kogure Y, Suzuki M, Hori M, Nakanishi A, Kamagata K . A strategy to optimize radiation exposure for non-contrast head CT: comparison with the Japanese diagnostic reference levels. Jpn J Radiol. 2016; 34(6):451-7. DOI: 10.1007/s11604-016-0545-3. View

4.
Mettler Jr F, Huda W, Yoshizumi T, Mahesh M . Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology. 2008; 248(1):254-63. DOI: 10.1148/radiol.2481071451. View

5.
Kalra M, Maher M, Toth T, Schmidt B, Westerman B, Morgan H . Techniques and applications of automatic tube current modulation for CT. Radiology. 2004; 233(3):649-57. DOI: 10.1148/radiol.2333031150. View