A Method to Generate Equivalent Energy Spectra and Filtration Models Based on Measurement for Multidetector CT Monte Carlo Dosimetry Simulations

Overview
Journal Med Phys
Specialty Biophysics
Date 2009 Jul 21
PMID 19610304
Citations 56
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called "equivalent" source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL1 and HVL2) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL1 and HVL2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types result in simulations with an average root mean square (RMS) error between the measured and simulated values of approximately 5% across all scanner and bowtie filter combinations, all kVps, both phantom sizes, and both measurement positions, while data provided from the manufacturers gave an average RMS error of approximately 12% pooled across all conditions. While there was no statistically significant difference between the two types of equivalent source models, both of these model types were shown to be statistically significantly different from the source model based on manufacturer's data. These results demonstrate that an equivalent source model based only on measured values can be used in place of manufacturer's data for Monte Carlo simulations for MDCT dosimetry.

Citing Articles

Accuracy of patient-specific CT organ doses from Monte Carlo simulations: influence of CT-based voxel models.

Verfaillie G, Rutten J, DAsseler Y, Bacher K Phys Eng Sci Med. 2024; 47(3):989-1000.

PMID: 38634980 PMC: 11408396. DOI: 10.1007/s13246-024-01422-z.


A comparison of breast and lung doses from chest CT scans using organ-based tube current modulation (OBTCM) vs. Automatic tube current modulation (ATCM).

Layman R, Hardy A, Kim H, Chou E, Bostani M, Cagnon C J Appl Clin Med Phys. 2021; 22(5):97-109.

PMID: 33939253 PMC: 8130227. DOI: 10.1002/acm2.13198.


Reference dataset for benchmarking fetal doses derived from Monte Carlo simulations of CT exams.

Hardy A, Bostani M, Angel E, Cagnon C, Sechopoulos I, McNitt-Gray M Med Phys. 2020; 48(1):523-532.

PMID: 33128259 PMC: 7902432. DOI: 10.1002/mp.14573.


The growing concern of radiation dose in paediatric dental and maxillofacial CBCT: an easy guide for daily practice.

Stratis A, Zhang G, Jacobs R, Bogaerts R, Bosmans H Eur Radiol. 2019; 29(12):7009-7018.

PMID: 31264018 DOI: 10.1007/s00330-019-06287-5.


Estimating fetal dose from tube current-modulated (TCM) and fixed tube current (FTC) abdominal/pelvis CT examinations.

Hardy A, Angel E, Bostani M, Cagnon C, McNitt-Gray M Med Phys. 2019; 46(6):2729-2743.

PMID: 30893477 PMC: 6561795. DOI: 10.1002/mp.13499.


References
1.
. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007; 37(2-4):1-332. DOI: 10.1016/j.icrp.2007.10.003. View

2.
Geleijns J, Salvado Artells M, Veldkamp W, Lopez Tortosa M, Calzado Cantera A . Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality. Eur Radiol. 2006; 16(10):2334-40. DOI: 10.1007/s00330-006-0217-2. View

3.
Hall E, Brenner D . Cancer risks from diagnostic radiology. Br J Radiol. 2008; 81(965):362-78. DOI: 10.1259/bjr/01948454. View

4.
Brenner D, Elliston C, Hall E, BERDON W . Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol. 2001; 176(2):289-96. DOI: 10.2214/ajr.176.2.1760289. View

5.
Angel E, Wellnitz C, Goodsitt M, Yaghmai N, DeMarco J, Cagnon C . Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte Carlo simulations estimating fetal dose for a range of gestational age and patient size. Radiology. 2008; 249(1):220-7. PMC: 2657855. DOI: 10.1148/radiol.2491071665. View