Pulmonary ailments are conventionally diagnosed by spirometry. The complex forceful breathing maneuver as well as the extreme cost of spirometry renders it unsuitable in many situations. This work is aimed to facilitate an emerging direction of tidal breathing-based pulmonary evaluation by designing a novel, equitable, precise and portable device for acquisition and analysis of directional tidal breathing patterns, in real time. The proposed system primarily uses an in-house designed blow pipe, 40-kHz air-coupled ultrasound transreceivers, and a radio frequency (RF) phase-gain integrated circuit (IC). Moreover, in order to achieve high sensitivity in a cost-effective design philosophy, we have exploited the phase measurement technique, instead of selecting the contemporary time-of-flight (TOF) measurement; since application of the TOF principle in tidal breathing assessments requires sub-micro to nanosecond time resolution. This approach, which depends on accurate phase measurement, contributed to enhanced sensitivity using a simple electronics design. The developed system has been calibrated using a standard 3-L calibration syringe. The parameters of this system are validated against a standard spirometer, with maximum percentage error below 16%. Further, the extracted respiratory parameters related to tidal breathing have been found to be comparable with relevant prior works. The error in detecting respiration rate only is 3.9% compared to manual evaluation. These encouraging insights reveal the definite potential of our tidal breathing pattern (TBP) prototype for measuring tidal breathing parameters in order to extend the reach of affordable healthcare in rural regions and developing areas.

Citing Articles

Ultrasound Sensors for Diaphragm Motion Tracking: An Application in Non-Invasive Respiratory Monitoring.

Shahshahani A, Laverdiere C, Bhadra S, Zilic Z Sensors (Basel). 2018; 18(8).

PMID: 30096945 PMC: 6111564. DOI: 10.3390/s18082617.


A Novel Approach to the Identification of Compromised Pulmonary Systems in Smokers by Exploiting Tidal Breathing Patterns.

Rakshit R, Khasnobish A, Chowdhury A, Sinharay A, Pal A, Chakravarty T Sensors (Basel). 2018; 18(5).

PMID: 29693559 PMC: 5981858. DOI: 10.3390/s18051322.

References
1.
Olden C, Symes E, Seddon P . Measuring tidal breathing parameters using a volumetric vest in neonates with and without lung disease. Pediatr Pulmonol. 2010; 45(11):1070-5. DOI: 10.1002/ppul.21272. View

2.
Thap T, Chung H, Jeong C, Hwang K, Kim H, Yoon K . High-Resolution Time-Frequency Spectrum-Based Lung Function Test from a Smartphone Microphone. Sensors (Basel). 2016; 16(8). PMC: 5017470. DOI: 10.3390/s16081305. View

3.
van der Ent C, Brackel H, Mulder P, Bogaard J . Improvement of tidal breathing pattern analysis in children with asthma by on-line automatic data processing. Eur Respir J. 1996; 9(6):1306-13. DOI: 10.1183/09031936.96.09061306. View

4.
Dei D, Grazzini G, Luzi G, Pieraccini M, Atzeni C, Boncinelli S . Non-contact detection of breathing using a microwave sensor. Sensors (Basel). 2012; 9(4):2574-85. PMC: 3348806. DOI: 10.3390/s90402574. View

5.
Pellegrino R, Viegi G, Brusasco V, Crapo R, Burgos F, Casaburi R . Interpretative strategies for lung function tests. Eur Respir J. 2005; 26(5):948-68. DOI: 10.1183/09031936.05.00035205. View