Tidal Breathing Flow Measurement in Awake Young Children by Using Impedance Pneumography

Overview
Date 2013 Oct 5
PMID 24092693
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Characteristics of tidal breathing (TB) relate to lung function and may be assessed even in young children. Thus far, the accuracy of impedance pneumography (IP) in recording TB flows in young children with or without bronchial obstruction has not been evaluated. The aim of this study was to evaluate the agreement between IP and direct flow measurement with pneumotachograph (PNT) in assessing TB flow and flow-derived indices relating to airway obstruction in young children. Tidal flow was recorded for 1 min simultaneously with IP and PNT during different phases of a bronchial challenge test with methacholine in 21 wheezy children aged 3 to 7 years. The agreement of IP with PNT was found to be excellent in direct flow signal comparison, the mean deviation from linearity ranging from 2.4 to 3.1% of tidal peak inspiratory flow. Methacholine-induced bronchoconstriction or consecutive bronchodilation induced only minor changes in the agreement. Between IP and PNT, the obstruction-related tidal flow indices were equally repeatable, and agreement was found to be high, with intraclass correlation coefficients for T PTEF/T E, V PTEF/V E, and parameter S being 0.94, 0.91, and 0.68, respectively. Methacholine-induced changes in tidal flow indices showed significant associations with changes in mechanical impedance of the respiratory system assessed by the oscillometric technique, with the highest correlation found in V PTEF/V E (r = -0.54; P < 0.005 and r = -0.55; P < 0.005 by using IP or PNT, respectively). The results indicate that IP can be considered as a valid method for recording tidal airflow profiles in young children with wheezing disorders.

Citing Articles

Assessing the Tidal Volume through Wearables: A Scoping Review.

Monaco V, Stefanini C Sensors (Basel). 2021; 21(12).

PMID: 34208468 PMC: 8233785. DOI: 10.3390/s21124124.


Expiratory variability index is associated with asthma risk, wheeze and lung function in infants with recurrent respiratory symptoms.

Seppa V, Gracia-Tabuenca J, Kotaniemi-Syrjanen A, Malmstrom K, Hult A, Pelkonen A ERJ Open Res. 2020; 6(4).

PMID: 33123560 PMC: 7569165. DOI: 10.1183/23120541.00167-2020.


Expiratory variability index (EVI) is associated with the severity of acute bronchial obstruction in small children: A proof-of-concept study.

Seppa V, Turkalj M, Hult A, Maloca Vuljanko I, Plavec D, Erceg D Pediatr Allergy Immunol. 2020; 31(6):636-642.

PMID: 32307738 PMC: 7496816. DOI: 10.1111/pai.13257.


Reduced expiratory variability index (EVI) is associated with controller medication withdrawal and symptoms in wheezy children aged 1-5 years.

Seppa V, Paassilta M, Kivisto J, Hult A, Viik J, Gracia-Tabuenca J Pediatr Allergy Immunol. 2020; 31(5):489-495.

PMID: 32068911 PMC: 7497189. DOI: 10.1111/pai.13234.


Airway obstruction is associated with reduced variability in specific parts of the tidal breathing flow-volume curve in young children.

Seppa V, Hult A, Gracia-Tabuenca J, Paassilta M, Viik J, Plavec D ERJ Open Res. 2019; 5(2).

PMID: 31218218 PMC: 6571449. DOI: 10.1183/23120541.00028-2019.