Body Composition Measurement Using Computed Tomography: Does the Phase of the Scan Matter?

Overview
Journal Nutrition
Date 2017 Aug 2
PMID 28760426
Citations 37
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The aim of this study was to determine, from the methodologic standpoint, the effect of the presence or absence of intravenous contrast on body composition variables obtained by analysis of computed tomography (CT) images.

Methods: Triphasic abdominal (noncontrast, arterial phase, and portovenous phase contrast) CT scans from 111 patients were analyzed by two independent assessors at the third lumbar vertebral level using SliceOmatic software (version 5.0, TomoVision, Montreal, Canada). Variables included skeletal muscle index (SMI), fat and fat-free mass (FM and FFM, respectively), and mean skeletal muscle Hounsfield units (SMHU).

Results: Mean SMHU was lowest in the noncontrast phase (29.4, standard deviation [SD] 8.9 HU), followed by arterial (32.4, SD 9.3 HU) then portovenous phases (34.9, SD 9.4 HU). The mean skeletal muscle attenuation was significantly different depending on the phase of the scan in which the images were obtained. Calculated FM was significantly lower in both arterial (28.6, SD 8.8 kg, P < 0.0001) and portovenous phase scans (28.5, SD 8.9 kg, P < 0.0001) when compared with noncontrast (29.2, SD 8.9 kg). The mean FFM was not significantly different as measured on noncontrast, arterial, or portovenous phase CT scans (48, SD 11.2; 48.1, SD 9.8; and 48.6, SD 10.2 kg, respectively). No difference was seen in SMI. Interobserver reliability was high.

Conclusions: The definition of myosteatosis should include a standardized phase of CT for analysis and this should be incorporated within its definition. However, as the magnitudes of the differences were relatively small, the effect of the phase of the scan on predicting outcome needs to be determined.

Citing Articles

Metabolic syndrome prediction based on body composition indices.

Alkhatib B, Orabi A, Agraib L, Al-Shami I J Egypt Public Health Assoc. 2024; 99(1):34.

PMID: 39710796 PMC: 11663827. DOI: 10.1186/s42506-024-00181-9.


Relationship between CT-derived cervical muscle mass and quality, systemic inflammation, and survival in symptomatic patients undergoing carotid endarterectomy.

Bradley N, Dosanj K, Chan S, Wilson A, Siddiqui T, Forsythe R BJS Open. 2024; 8(5).

PMID: 39441694 PMC: 11498072. DOI: 10.1093/bjsopen/zrae114.


Does computed tomography-derived volumometry and densitometry of psoas muscle really correlate with complications in rectal cancer patients after elective surgery?.

Kotek J, Lochman P, Hulek M, Sirovy M, Merkl T, cermakova E J Clin Imaging Sci. 2024; 14:26.

PMID: 39108316 PMC: 11301790. DOI: 10.25259/JCIS_43_2024.


Fat quantification in dual-layer detector spectral CT: How to handle iron overload, varying tube voltage and radiation dose Indices.

Molwitz I, Campbell G, Knopp T, Schubert N, Erley J, Loser A PLoS One. 2024; 19(5):e0302863.

PMID: 38781228 PMC: 11115214. DOI: 10.1371/journal.pone.0302863.


Dual-Energy CT muscle fat fraction as a new imaging biomarker of body composition and survival predictor in critically ill patients.

Erley J, Roedl K, Ozga A, de Heer G, Schubert N, Breckow J Eur Radiol. 2024; 34(11):7408-7418.

PMID: 38777903 PMC: 11519288. DOI: 10.1007/s00330-024-10779-4.