A Detailed Algorithm for Vital Sign Monitoring of a Stationary/Non-Stationary Human Through IR-UWB Radar

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2017 Feb 7
PMID 28165416
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

The vital sign monitoring through Impulse Radio Ultra-Wide Band (IR-UWB) radar provides continuous assessment of a patient's respiration and heart rates in a non-invasive manner. In this paper, IR UWB radar is used for monitoring respiration and the human heart rate. The breathing and heart rate frequencies are extracted from the signal reflected from the human body. A Kalman filter is applied to reduce the measurement noise from the vital signal. An algorithm is presented to separate the heart rate signal from the breathing harmonics. An auto-correlation based technique is applied for detecting random body movements (RBM) during the measurement process. Experiments were performed in different scenarios in order to show the validity of the algorithm. The vital signs were estimated for the signal reflected from the chest, as well as from the back side of the body in different experiments. The results from both scenarios are compared for respiration and heartbeat estimation accuracy.

Citing Articles

Innovative Seatbelt-Integrated Metasurface Radar for Enhanced In-Car Healthcare Monitoring.

Asyari R, Simorangkir R, Teichmann D Sensors (Basel). 2024; 24(23).

PMID: 39686031 PMC: 11644054. DOI: 10.3390/s24237494.


Deep Kronecker LeNet for human motion classification with feature extraction.

Pardhu T, Kumar V, Durbhakula K Sci Rep. 2024; 14(1):29102.

PMID: 39582072 PMC: 11586406. DOI: 10.1038/s41598-024-80195-7.


Enhancing Road Safety: Fast and Accurate Noncontact Driver HRV Detection Based on Huber-Kalman and Autocorrelation Algorithms.

Luo Y, Yang Y, Ma Y, Huang R, Qi A, Ma M Biomimetics (Basel). 2024; 9(8).

PMID: 39194460 PMC: 11351964. DOI: 10.3390/biomimetics9080481.


Evaluation of Lateral Radar Positioning for Vital Sign Monitoring: An Empirical Study.

Hornig L, Szmola B, Patzold W, Vox J, Wolf K Sensors (Basel). 2024; 24(11).

PMID: 38894339 PMC: 11175299. DOI: 10.3390/s24113548.


Introducing the Pi-CON Methodology to Overcome Usability Deficits during Remote Patient Monitoring.

Baumann S, Stone R, Kim J Sensors (Basel). 2024; 24(7).

PMID: 38610471 PMC: 11014368. DOI: 10.3390/s24072260.


References
1.
Zito D, Pepe D, Neri B, De Rossi D, Lanata A, Tognetti A . Wearable system-on-a-chip UWB radar for health care and its application to the safety improvement of emergency operators. Annu Int Conf IEEE Eng Med Biol Soc. 2007; 2007:2651-4. DOI: 10.1109/IEMBS.2007.4352874. View

2.
Hu X, Jin T . Short-Range Vital Signs Sensing Based on EEMD and CWT Using IR-UWB Radar. Sensors (Basel). 2016; 16(12). PMC: 5191006. DOI: 10.3390/s16122025. View

3.
Kocur D, Svecova M, Rovnakova J . Through-the-wall localization of a moving target by two independent ultra wideband (UWB) radar systems. Sensors (Basel). 2013; 13(9):11969-97. PMC: 3820146. DOI: 10.3390/s130911969. View

4.
Li X, Dengyu Qiao , Li Y . Macro-motion detection using ultra-wideband impulse radar. Annu Int Conf IEEE Eng Med Biol Soc. 2015; 2014:2237-40. DOI: 10.1109/EMBC.2014.6944064. View

5.
Choliz J, Hernandez A, Valdovinos A . A framework for UWB-based communication and location tracking systems for wireless sensor networks. Sensors (Basel). 2011; 11(9):9045-68. PMC: 3231499. DOI: 10.3390/s110909045. View