» Articles » PMID: 22163501

Detecting Vital Signs with Wearable Wireless Sensors

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2011 Dec 14
PMID 22163501
Citations 73
Authors
Affiliations
Soon will be listed here.
Abstract

The emergence of wireless technologies and advancements in on-body sensor design can enable change in the conventional health-care system, replacing it with wearable health-care systems, centred on the individual. Wearable monitoring systems can provide continuous physiological data, as well as better information regarding the general health of individuals. Thus, such vital-sign monitoring systems will reduce health-care costs by disease prevention and enhance the quality of life with disease management. In this paper, recent progress in non-invasive monitoring technologies for chronic disease management is reviewed. In particular, devices and techniques for monitoring blood pressure, blood glucose levels, cardiac activity and respiratory activity are discussed; in addition, on-body propagation issues for multiple sensors are presented.

Citing Articles

Monoolein-Based Wireless Capacitive Sensor for Probing Skin Hydration.

Chaturvedi V, Falk M, Bjorklund S, Gonzalez-Martinez J, Shleev S Sensors (Basel). 2024; 24(14).

PMID: 39065849 PMC: 11280606. DOI: 10.3390/s24144449.


Mobile Diagnostic Clinics.

Baron R, Haick H ACS Sens. 2024; 9(6):2777-2792.

PMID: 38775426 PMC: 11217950. DOI: 10.1021/acssensors.4c00636.


Unobtrusive Sensors for Synchronous Monitoring of Different Breathing Parameters in Care Environments.

Saied I, Alzaabi A, Arslan T Sensors (Basel). 2024; 24(7).

PMID: 38610446 PMC: 11014059. DOI: 10.3390/s24072233.


The Role of Wearable Sensors in the Future Primary Healthcare - Preferences of the Adult Swiss Population: A Mixed Methods Approach.

Matti C, Essig S, Fohn Z, Balthasar A J Med Syst. 2023; 47(1):111.

PMID: 37907653 PMC: 10618354. DOI: 10.1007/s10916-023-01998-1.


Predicting Respiratory Rate from Electrocardiogram and Photoplethysmogram Using a Transformer-Based Model.

Zhao Q, Liu F, Song Y, Fan X, Wang Y, Yao Y Bioengineering (Basel). 2023; 10(9).

PMID: 37760126 PMC: 10525435. DOI: 10.3390/bioengineering10091024.


References
1.
Newman J, Turner A . Home blood glucose biosensors: a commercial perspective. Biosens Bioelectron. 2005; 20(12):2435-53. DOI: 10.1016/j.bios.2004.11.012. View

2.
Shaltis P, Reisner A, Asada H . Wearable, cuff-less PPG-based blood pressure monitor with novel height sensor. Conf Proc IEEE Eng Med Biol Soc. 2007; 2006:908-11. DOI: 10.1109/IEMBS.2006.260027. View

3.
Arnold M, Burmeister J, Small G . Phantom glucose calibration models from simulated noninvasive human near-infrared spectra. Anal Chem. 1998; 70(9):1773-81. DOI: 10.1021/ac9710801. View

4.
Hao Y, Foster R . Wireless body sensor networks for health-monitoring applications. Physiol Meas. 2008; 29(11):R27-56. DOI: 10.1088/0967-3334/29/11/R01. View

5.
Shaltis P, Reisner A, Asada H . Calibration of the photoplethysmogram to arterial blood pressure: capabilities and limitations for continuous pressure monitoring. Conf Proc IEEE Eng Med Biol Soc. 2007; 2005:3970-3. DOI: 10.1109/IEMBS.2005.1615331. View