» Articles » PMID: 24514883

Techniques for Clutter Suppression in the Presence of Body Movements During the Detection of Respiratory Activity Through UWB Radars

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2014 Feb 12
PMID 24514883
Citations 42
Authors
Affiliations
Soon will be listed here.
Abstract

This paper focuses on the feasibility of tracking the chest wall movement of a human subject during respiration from the waveforms recorded using an impulse-radio (IR) ultra-wideband radar. The paper describes the signal processing to estimate sleep apnea detection and breathing rate. Some techniques to solve several problems in these types of measurements, such as the clutter suppression, body movement and body orientation detection are described. Clutter suppression is achieved using a moving averaging filter to dynamically estimate it. The artifacts caused by body movements are removed using a threshold method before analyzing the breathing signal. The motion is detected using the time delay that maximizes the received signal after a clutter removing algorithm is applied. The periods in which the standard deviations of the time delay exceed a threshold are considered macro-movements and they are neglected. The sleep apnea intervals are detected when the breathing signal is below a threshold. The breathing rate is determined from the robust spectrum estimation based on Lomb periodogram algorithm. On the other hand the breathing signal amplitude depends on the body orientation respect to the antennas, and this could be a problem. In this case, in order to maximize the signal-to-noise ratio, multiple sensors are proposed to ensure that the backscattered signal can be detected by at least one sensor, regardless of the direction the human subject is facing. The feasibility of the system is compared with signals recorded by a microphone.

Citing Articles

Enhanced Vital Parameter Estimation Using Short-Range Radars with Advanced Motion Compensation and Super-Resolution Techniques.

Yoon S, Baek S, Choi I, Kim S, Koo B, Baek Y Sensors (Basel). 2024; 24(20).

PMID: 39460245 PMC: 11511147. DOI: 10.3390/s24206765.


A Review of Patient Bed Sensors for Monitoring of Vital Signs.

Recmanik M, Martinek R, Nedoma J, Jaros R, Pelc M, Hajovsky R Sensors (Basel). 2024; 24(15).

PMID: 39123813 PMC: 11314724. DOI: 10.3390/s24154767.


Integrated Sensing and Communication: Enabling Techniques, Applications, Tools and Data Sets, Standardization, and Future Directions.

Wang J, Varshney N, Gentile C, Blandino S, Chuang J, Golmie N IEEE Internet Things J. 2023; 9(23).

PMID: 37275265 PMC: 10236932. DOI: 10.1109/jiot.2022.3190845.


Convolutional Neural Networks for the Real-Time Monitoring of Vital Signs Based on Impulse Radio Ultrawide-Band Radar during Sleep.

Choi S, Yoon H Sensors (Basel). 2023; 23(6).

PMID: 36991833 PMC: 10052197. DOI: 10.3390/s23063116.


Research on Ultra-Wideband Radar Echo Signal Processing Method Based on P-Order Extraction and VMD.

Qi Q, Zhao Y, Zhang L, Yang Z, Sun L, Jia X Sensors (Basel). 2022; 22(18).

PMID: 36146076 PMC: 9503521. DOI: 10.3390/s22186726.


References
1.
Zito D, Pepe D, Mincica M, Zito F, Tognetti A, Lanata A . SoC CMOS UWB Pulse Radar Sensor for Contactless Respiratory Rate Monitoring. IEEE Trans Biomed Circuits Syst. 2013; 5(6):503-10. DOI: 10.1109/TBCAS.2011.2176937. View

2.
Philip P, Sagaspe P, Lagarde E, Leger D, Ohayon M, Bioulac B . Sleep disorders and accidental risk in a large group of regular registered highway drivers. Sleep Med. 2010; 11(10):973-9. DOI: 10.1016/j.sleep.2010.07.010. View

3.
De Groote A, Wantier M, Cheron G, Estenne M, Paiva M . Chest wall motion during tidal breathing. J Appl Physiol (1985). 1998; 83(5):1531-7. DOI: 10.1152/jappl.1997.83.5.1531. View

4.
Laguna P, Moody G, Mark R . Power spectral density of unevenly sampled data by least-square analysis: performance and application to heart rate signals. IEEE Trans Biomed Eng. 1998; 45(6):698-715. DOI: 10.1109/10.678605. View

5.
Kocur D, Svecova M, Rovnakova J . Through-the-wall localization of a moving target by two independent ultra wideband (UWB) radar systems. Sensors (Basel). 2013; 13(9):11969-97. PMC: 3820146. DOI: 10.3390/s130911969. View