» Authors » Mark van Gastel

Mark van Gastel

Explore the profile of Mark van Gastel including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 11
Citations 116
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Que S, van Meulen F, Verkruijsse W, van Gastel M, Overeem S, Zinger S, et al.
Sensors (Basel) . 2023 Jul; 23(14). PMID: 37514607
Instantaneous heart rate (IHR) has been investigated for sleep applications, such as sleep apnea detection and sleep staging. To ensure the comfort of the patient during sleep, it is desirable...
2.
van Gastel M, Verkruysse W
Biomed Opt Express . 2023 Jan; 13(12):6791-6802. PMID: 36589571
Camera-based blood oxygen saturation (SpO) monitoring allows reliable measurements without touching the skin and is therefore very attractive when there is a risk of cross-infection, in case of fragile skin,...
3.
van der Stel S, Lai M, Groen H, Witteveen M, Kuhlmann K, Grotenhuis B, et al.
J Surg Res . 2022 Dec; 283:705-712. PMID: 36462380
Introduction: Anastomotic leakage after gastrointestinal surgery has a high impact on patient's quality of life and its origin is associated with inadequate perfusion. Imaging photoplethysmography (iPPG) is a noninvasive imaging...
4.
Que S, Verkruijsse W, van Gastel M, Stuijk S
Annu Int Conf IEEE Eng Med Biol Soc . 2022 Sep; 2022:4604-4610. PMID: 36086409
Monitoring of heart rate in patients in the general ward is necessary to assess the clinical situation of the patient. Currently, this is done via spot-checks on pulse rate manually...
5.
Lai M, van der Stel S, Groen H, van Gastel M, Kuhlmann K, Ruers T, et al.
J Imaging . 2022 Apr; 8(4). PMID: 35448221
Surgical excision is the golden standard for treatment of intestinal tumors. In this surgical procedure, inadequate perfusion of the anastomosis can lead to postoperative complications, such as anastomotic leakages. Imaging...
6.
van Gastel M, Wang W, Verkruysse W
Biomed Opt Express . 2021 Jun; 12(5):2813-2824. PMID: 34168904
Camera-based pulse-oximetry enables contactless estimation of peripheral oxygen saturation (SpO). Because of the lack of readily available and affordable single-optics multi-spectral cameras, custom-made multi-camera setups with different optical filters are...
7.
van Gastel M, Stuijk S, Overeem S, van Dijk J, van Gilst M, de Haan G
IEEE J Biomed Health Inform . 2020 Dec; 25(5):1409-1418. PMID: 33338025
Polysomnography (PSG) is the current gold standard for the diagnosis of sleep disorders. However, this multi-parametric sleep monitoring tool also has some drawbacks, e.g. it limits the patient's mobility during...
8.
van Gastel M, Stuijk S, de Haan G
Biomed Opt Express . 2018 Jan; 9(1):102-119. PMID: 29359090
Camera-based pulse-oximetry has recently shown to be feasible, even when the signal is corrupted by noise and motion artifacts. Earlier work showed that using three instead of the common two...
9.
van Gastel M, Stuijk S, de Haan G
Biomed Opt Express . 2016 Dec; 7(12):4941-4957. PMID: 28018717
Continuous monitoring of respiration is essential for early detection of critical illness. Current methods require sensors attached to the body and/or are not robust to subject motion. Alternative camera-based solutions...
10.
van Gastel M, Stuijk S, de Haan G
Sci Rep . 2016 Dec; 6:38609. PMID: 27924930
Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO) with a camera has been demonstrated. Both contact and remote measurements, however,...