Mathematical Detection of Aortic Valve Opening (B Point) in Impedance Cardiography: A Comparison of Three Popular Algorithms

Overview
Specialty Psychiatry
Date 2016 Dec 4
PMID 27914174
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

The preejection period (PEP) is an index of left ventricle contractility widely used in psychophysiological research. Its computation requires detecting the moment when the aortic valve opens, which coincides with the B point in the first derivative of impedance cardiogram (ICG). Although this operation has been traditionally made via visual inspection, several algorithms based on derivative calculations have been developed to enable an automatic performance of the task. However, despite their popularity, data about their empirical validation are not always available. The present study analyzes the performance in the estimation of the aortic valve opening of three popular algorithms, by comparing their performance with the visual detection of the B point made by two independent scorers. Algorithm 1 is based on the first derivative of the ICG, Algorithm 2 on the second derivative, and Algorithm 3 on the third derivative. Algorithm 3 showed the highest accuracy rate (78.77%), followed by Algorithm 1 (24.57%) and Algorithm 2 (13.82%). In the automatic computation of PEP, Algorithm 2 resulted in significantly more missed cycles (48.57%) than Algorithm 1 (6.3%) and Algorithm 3 (3.5%). Algorithm 2 also estimated a significantly lower average PEP (70 ms), compared with the values obtained by Algorithm 1 (119 ms) and Algorithm 3 (113 ms). Our findings indicate that the algorithm based on the third derivative of the ICG performs significantly better. Nevertheless, a visual inspection of the signal proves indispensable, and this article provides a novel visual guide to facilitate the manual detection of the B point.

Citing Articles

Incorporating Virtual Reality Agents During a Dichotic Speech Reception Task: Insights From the Heart.

Plain B, Pielage H, Zekveld A, Richter M, Bhuiyan T, van de Ven S Ear Hear. 2024; 46(2):444-460.

PMID: 39565283 PMC: 11825489. DOI: 10.1097/AUD.0000000000001597.


ICG signal denoising based on ICEEMDAN and PSO-VMD methods.

Li X, Ni R, Ji Z Phys Eng Sci Med. 2024; 47(4):1547-1556.

PMID: 39115738 DOI: 10.1007/s13246-024-01467-0.


Impedance cardiogram based exploration of cardiac mechanisms in post-traumatic stress disorder during trauma recall.

Sheikh S, Shah A, Douglas Bremner J, Vaccarino V, Inan O, Clifford G Psychophysiology. 2023; 61(4):e14488.

PMID: 37986190 PMC: 10939951. DOI: 10.1111/psyp.14488.


A New Method of Identifying Characteristic Points in the Impedance Cardiography Signal Based on Empirical Mode Decomposition.

Trybek P, Sobotnicka E, Wawrzkiewicz-Jalowiecka A, Machura L, Feige D, Sobotnicki A Sensors (Basel). 2023; 23(2).

PMID: 36679466 PMC: 9861967. DOI: 10.3390/s23020675.


An Effective Method of Detecting Characteristic Points of Impedance Cardiogram Verified in the Clinical Pilot Study.

Karpiel I, Richter-Laskowska M, Feige D, Gacek A, Sobotnicki A Sensors (Basel). 2022; 22(24).

PMID: 36560238 PMC: 9782651. DOI: 10.3390/s22249872.