» Articles » PMID: 27650280

Quantification of Myocardial Blood Flow with (82)Rb: Validation with (15)O-water Using Time-of-flight and Point-spread-function Modeling

Overview
Journal EJNMMI Res
Date 2016 Sep 22
PMID 27650280
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Background: We quantified myocardial blood flow with (82)Rb PET using parameters of the generalized Renkin-Crone model estimated from (82)Rb and (15)O-water images reconstructed with time-of-flight and point spread function modeling. Previous estimates of rubidium extraction have used older-generation scanners without time-of-flight or point spread function modeling. We validated image-derived input functions with continuously collected arterial samples.

Methods: Nine healthy subjects were scanned at rest and under pharmacological stress on the Siemens Biograph mCT with (82)Rb and (15)O-water PET, undergoing arterial blood sampling with each scan. Image-derived input functions were estimated from the left ventricle cavity and corrected with tracer-specific population-based scale factors determined from arterial data. Kinetic parametric images were generated from the dynamic PET images by fitting the one-tissue compartment model to each voxel's time activity curve. Mean myocardial blood flow was determined from each subject's (15)O-water k 2 images. The parameters of the generalized Renkin-Crone model were estimated from these water-based flows and mean myocardial (82)Rb K 1 estimates.

Results: Image-derived input functions showed improved agreement with arterial measurements after a scale correction. The Renkin-Crone model fit (a = 0.77, b = 0.39) was similar to those previously published, though b was lower.

Conclusions: We have presented parameter estimates for the generalized Renkin-Crone model of extraction for (82)Rb PET using human (82)Rb and (15)O-water PET from high-resolution images using a state-of-the-art time-of-flight-capable scanner. These results provide a state-of-the-art methodology for myocardial blood flow measurement with (82)Rb PET.

Citing Articles

Noise-aware dynamic image denoising and positron range correction for Rubidium-82 cardiac PET imaging via self-supervision.

Xie H, Guo L, Velo A, Liu Z, Liu Q, Guo X Med Image Anal. 2024; 100:103391.

PMID: 39579623 PMC: 11647511. DOI: 10.1016/j.media.2024.103391.


TAI-GAN: A Temporally and Anatomically Informed Generative Adversarial Network for early-to-late frame conversion in dynamic cardiac PET inter-frame motion correction.

Guo X, Shi L, Chen X, Liu Q, Zhou B, Xie H Med Image Anal. 2024; 96:103190.

PMID: 38820677 PMC: 11180595. DOI: 10.1016/j.media.2024.103190.


TAI-GAN: Temporally and Anatomically Informed GAN for Early-to-Late Frame Conversion in Dynamic Cardiac PET Motion Correction.

Guo X, Shi L, Chen X, Zhou B, Liu Q, Xie H Simul Synth Med Imaging. 2024; 14288:64-74.

PMID: 38464964 PMC: 10923183. DOI: 10.1007/978-3-031-44689-4_7.


Anti-inflammatory effect of biologic therapy in patients with psoriatic disease: A prospective cohort FDG PET study.

Boczar K, Beanlands R, Glassman S, Wang J, Zeng W, deKemp R J Nucl Cardiol. 2023; 30(4):1642-1652.

PMID: 36754934 PMC: 10372102. DOI: 10.1007/s12350-023-03204-8.


A retrospective evaluation of Bayesian-penalized likelihood reconstruction for [O]HO myocardial perfusion imaging.

Siekkinen R, Han C, Maaniitty T, Teras M, Knuuti J, Saraste A J Nucl Cardiol. 2023; 30(4):1602-1612.

PMID: 36656496 PMC: 10371909. DOI: 10.1007/s12350-022-03164-5.


References
1.
Armstrong I, Tonge C, Arumugam P . Impact of point spread function modeling and time-of-flight on myocardial blood flow and myocardial flow reserve measurements for rubidium-82 cardiac PET. J Nucl Cardiol. 2014; 21(3):467-74. DOI: 10.1007/s12350-014-9858-8. View

2.
Katoh C, Yoshinaga K, Klein R, Kasai K, Tomiyama Y, Manabe O . Quantification of regional myocardial blood flow estimation with three-dimensional dynamic rubidium-82 PET and modified spillover correction model. J Nucl Cardiol. 2012; 19(4):763-74. DOI: 10.1007/s12350-012-9558-1. View

3.
Bergmann S, Fox K, RAND A, McElvany K, Welch M, Markham J . Quantification of regional myocardial blood flow in vivo with H215O. Circulation. 1984; 70(4):724-33. DOI: 10.1161/01.cir.70.4.724. View

4.
Lortie M, Beanlands R, Yoshinaga K, Klein R, DaSilva J, deKemp R . Quantification of myocardial blood flow with 82Rb dynamic PET imaging. Eur J Nucl Med Mol Imaging. 2007; 34(11):1765-74. DOI: 10.1007/s00259-007-0478-2. View

5.
Iida H, Kanno I, Takahashi A, Miura S, Murakami M, Takahashi K . Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect. Circulation. 1988; 78(1):104-15. DOI: 10.1161/01.cir.78.1.104. View