Noise-aware Dynamic Image Denoising and Positron Range Correction for Rubidium-82 Cardiac PET Imaging Via Self-supervision

Overview
Journal Med Image Anal
Publisher Elsevier
Specialty Radiology
Date 2024 Nov 23
PMID 39579623
Authors
Affiliations
Soon will be listed here.
Abstract

Rubidium-82 (Rb) is a radioactive isotope widely used for cardiac PET imaging. Despite numerous benefits of Rb, there are several factors that limits its image quality and quantitative accuracy. First, the short half-life of Rb results in noisy dynamic frames. Low signal-to-noise ratio would result in inaccurate and biased image quantification. Noisy dynamic frames also lead to highly noisy parametric images. The noise levels also vary substantially in different dynamic frames due to radiotracer decay and short half-life. Existing denoising methods are not applicable for this task due to the lack of paired training inputs/labels and inability to generalize across varying noise levels. Second, Rb emits high-energy positrons. Compared with other tracers such as F, Rb travels a longer distance before annihilation, which negatively affect image spatial resolution. Here, the goal of this study is to propose a self-supervised method for simultaneous (1) noise-aware dynamic image denoising and (2) positron range correction for Rb cardiac PET imaging. Tested on a series of PET scans from a cohort of normal volunteers, the proposed method produced images with superior visual quality. To demonstrate the improvement in image quantification, we compared image-derived input functions (IDIFs) with arterial input functions (AIFs) from continuous arterial blood samples. The IDIF derived from the proposed method led to lower AUC differences, decreasing from 11.09% to 7.58% on average, compared to the original dynamic frames. The proposed method also improved the quantification of myocardium blood flow (MBF), as validated against O-water scans, with mean MBF differences decreased from 0.43 to 0.09, compared to the original dynamic frames. We also conducted a generalizability experiment on 37 patient scans obtained from a different country using a different scanner. The presented method enhanced defect contrast and resulted in lower regional MBF in areas with perfusion defects. Lastly, comparison with other related methods is included to show the effectiveness of the proposed method.

References
1.
Herzog B, Husmann L, Valenta I, Gaemperli O, Siegrist P, Tay F . Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve. J Am Coll Cardiol. 2009; 54(2):150-6. DOI: 10.1016/j.jacc.2009.02.069. View

2.
Hoek R, van Diemen P, Raijmakers P, Driessen R, Somsen Y, W de Winter R . Determining Hemodynamically Significant Coronary Artery Disease: Patient-Specific Cutoffs in Quantitative Myocardial Blood Flow Using [O]HO PET Imaging. J Nucl Med. 2024; 65(7):1113-1121. DOI: 10.2967/jnumed.123.267195. View

3.
Murthy V, Bateman T, Beanlands R, Berman D, Borges-Neto S, Chareonthaitawee P . Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC. J Nucl Med. 2017; 59(2):273-293. DOI: 10.2967/jnumed.117.201368. View

4.
Zhou L, Schaefferkoetter J, Tham I, Huang G, Yan J . Supervised learning with cyclegan for low-dose FDG PET image denoising. Med Image Anal. 2020; 65:101770. DOI: 10.1016/j.media.2020.101770. View

5.
Gong K, Guan J, Liu C, Qi J . PET Image Denoising Using a Deep Neural Network Through Fine Tuning. IEEE Trans Radiat Plasma Med Sci. 2020; 3(2):153-161. PMC: 7402614. DOI: 10.1109/TRPMS.2018.2877644. View