» Articles » PMID: 27469265

Dose-rate-dependent Damage of Cerium Dioxide in the Scanning Transmission Electron Microscope

Overview
Journal Ultramicroscopy
Publisher Elsevier
Specialty Radiology
Date 2016 Jul 30
PMID 27469265
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Beam damage caused by energetic electrons in the transmission electron microscope is a fundamental constraint limiting the collection of artifact-free information. Through understanding the influence of the electron beam, experimental routines may be adjusted to improve the data collection process. Investigations of CeO indicate that there is not a critical dose required for the accumulation of electron beam damage. Instead, measurements using annular dark field scanning transmission electron microscopy and electron energy loss spectroscopy demonstrate that the onset of measurable damage occurs when a critical dose rate is exceeded. The mechanism behind this phenomenon is that oxygen vacancies created by exposure to a 300keV electron beam are actively annihilated as the sample re-oxidizes in the microscope environment. As a result, only when the rate of vacancy creation exceeds the recovery rate will beam damage begin to accumulate. This observation suggests that dose-intensive experiments can be accomplished without disrupting the native structure of the sample when executed using dose rates below the appropriate threshold. Furthermore, the presence of an encapsulating carbonaceous layer inhibits processes that cause beam damage, markedly increasing the dose rate threshold for the accumulation of damage.

Citing Articles

in situ observation of reversible phase transitions in Gd-doped ceria driven by electron beam irradiation.

Ran K, Zeng F, Jin L, Baumann S, Meulenberg W, Mayer J Nat Commun. 2024; 15(1):8156.

PMID: 39289372 PMC: 11408598. DOI: 10.1038/s41467-024-52386-3.


Cryo-electron tomography related radiation-damage parameters for individual-molecule 3D structure determination.

Xue H, Zhang M, Liu J, Wang J, Ren G Front Chem. 2022; 10:889203.

PMID: 36110139 PMC: 9468540. DOI: 10.3389/fchem.2022.889203.


A novel nondestructive diagnostic method for mega-electron-volt ultrafast electron diffraction.

Yang X, Li J, Fedurin M, Smaluk V, Yu L, Wu L Sci Rep. 2019; 9(1):17223.

PMID: 31748616 PMC: 6868275. DOI: 10.1038/s41598-019-53824-9.


Atomic scale insights into structure instability and decomposition pathway of methylammonium lead iodide perovskite.

Chen S, Zhang X, Zhao J, Zhang Y, Kong G, Li Q Nat Commun. 2018; 9(1):4807.

PMID: 30442950 PMC: 6237850. DOI: 10.1038/s41467-018-07177-y.


Approaches for the quantitative analysis of oxidation state in cerium oxide nanomaterials.

Sims C, Maier R, Johnston-Peck A, Gorham J, Hackley V, Nelson B Nanotechnology. 2018; 30(8):085703.

PMID: 30240366 PMC: 6351072. DOI: 10.1088/1361-6528/aae364.


References
1.
Egerton R . Control of radiation damage in the TEM. Ultramicroscopy. 2012; 127:100-8. DOI: 10.1016/j.ultramic.2012.07.006. View

2.
Mkhoyan K, Maccagnano-Zacher S, Kirkland E, Silcox J . Effects of amorphous layers on ADF-STEM imaging. Ultramicroscopy. 2008; 108(8):791-803. DOI: 10.1016/j.ultramic.2008.01.007. View

3.
Haigh S, Young N, Sawada H, Takayanagi K, Kirkland A . Imaging the active surfaces of cerium dioxide nanoparticles. Chemphyschem. 2011; 12(13):2397-9. DOI: 10.1002/cphc.201100376. View

4.
Goris B, Turner S, Bals S, Van Tendeloo G . Three-dimensional valency mapping in ceria nanocrystals. ACS Nano. 2014; 8(10):10878-84. DOI: 10.1021/nn5047053. View

5.
de Jonge N, Poirier-Demers N, Demers H, Peckys D, Drouin D . Nanometer-resolution electron microscopy through micrometers-thick water layers. Ultramicroscopy. 2010; 110(9):1114-9. PMC: 2917648. DOI: 10.1016/j.ultramic.2010.04.001. View