Effects of Amorphous Layers on ADF-STEM Imaging

Overview
Journal Ultramicroscopy
Publisher Elsevier
Specialty Radiology
Date 2008 Apr 1
PMID 18374489
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

A study of high-resolution ADF imaging in uncorrected and aberration-corrected STEMs was carried out by multislice simulation. The presence of amorphous layers at the surface of a crystalline specimen is shown to significantly alter the visibility of the atomic columns. After propagating through an amorphous layer a portion of the beam passes without any alteration while scattered electrons introduce a Gaussian background. The dependence of the image contrast on the crystal structure, orientation and the types of the atoms present in the crystal was studied. In the case of uncorrected probes an amorphous layer thicker than 200 A is necessary to achieve considerable reduction of the visibility of the atomic columns, but with aberration-corrected probes only 60 A is necessary. With changes in defocus, crystalline specimens with amorphous layers on the top can also be imaged and high-resolution ADF images can be obtained. An amorphous layer at the beam entry surface affects the ADF image more than that of an amorphous layer at the exit surface. Approximately linear reduction of the contrast (with a slop of 1) is expected with increased thickness of amorphous layer.

Citing Articles

Influence of plasmon excitations on atomic-resolution quantitative 4D scanning transmission electron microscopy.

Beyer A, Krause F, Robert H, Firoozabadi S, Grieb T, Kukelhan P Sci Rep. 2020; 10(1):17890.

PMID: 33087734 PMC: 7578809. DOI: 10.1038/s41598-020-74434-w.


Microstructure characterization of BaSnO thin films on LaAlO and PrScO substrates from transmission electron microscopy.

Yun H, Ganguly K, Postiglione W, Jalan B, Leighton C, Mkhoyan K Sci Rep. 2018; 8(1):10245.

PMID: 29980713 PMC: 6035271. DOI: 10.1038/s41598-018-28520-9.


Dose-rate-dependent damage of cerium dioxide in the scanning transmission electron microscope.

Johnston-Peck A, DuChene J, Roberts A, Wei W, Herzing A Ultramicroscopy. 2016; 170:1-9.

PMID: 27469265 PMC: 5091080. DOI: 10.1016/j.ultramic.2016.07.002.


Extreme mobility enhancement of two-dimensional electron gases at oxide interfaces by charge-transfer-induced modulation doping.

Chen Y, Trier F, Wijnands T, Green R, Gauquelin N, Egoavil R Nat Mater. 2015; 14(8):801-6.

PMID: 26030303 DOI: 10.1038/nmat4303.


Simulating realistic imaging conditions for in situ liquid microscopy.

Welch D, Faller R, Evans J, Browning N Ultramicroscopy. 2013; 135:36-42.

PMID: 23872040 PMC: 3808501. DOI: 10.1016/j.ultramic.2013.05.010.