Computational Fluid Dynamics Simulations of Blood Flow Regularized by 3D Phase Contrast MRI
Overview
Affiliations
Background: Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations. CFD provides arbitrarily high resolution, but its accuracy hinges on model assumptions, while velocity fields measured with PC-MRI generally do not satisfy the equations of fluid dynamics, provide limited resolution, and suffer from partial volume effects. The purpose of this study is to develop a proof-of-concept numerical procedure for constructing a simulated flow field that is influenced by both direct PC-MRI measurements and a fluid physics model, thereby taking advantage of both the accuracy of PC-MRI and the high spatial resolution of CFD. The use of the proposed approach in regularizing 3D flow fields is evaluated.
Methods: The proposed algorithm incorporates both a Newtonian fluid physics model and a linear PC-MRI signal model. The model equations are solved numerically using a modified CFD algorithm. The numerical solution corresponds to the optimal solution of a generalized Tikhonov regularization, which provides a flow field that satisfies the flow physics equations, while being close enough to the measured PC-MRI velocity profile. The feasibility of the proposed approach is demonstrated on data from the carotid bifurcation of one healthy volunteer, and also from a pulsatile carotid flow phantom.
Results: The proposed solver produces flow fields that are in better agreement with direct PC-MRI measurements than CFD alone, and converges faster, while closely satisfying the fluid dynamics equations. For the implementation that provided the best results, the signal-to-error ratio (with respect to the PC-MRI measurements) in the phantom experiment was 6.56 dB higher than that of conventional CFD; in the in vivo experiment, it was 2.15 dB higher.
Conclusions: The proposed approach allows partial or complete measurements to be incorporated into a modified CFD solver, for improving the accuracy of the resulting flow fields estimates. This can be used for reducing scan time, increasing the spatial resolution, and/or denoising the PC-MRI measurements.
Liu Y, Wu B, Wu S, Liu Z, Wang P, Lv Y Medicine (Baltimore). 2024; 103(48):e40613.
PMID: 39612378 PMC: 11608718. DOI: 10.1097/MD.0000000000040613.
Super-Resolving and Denoising 4D flow MRI of Neurofluids Using Physics-Guided Neural Networks.
Patel N, Bartusiak E, Rothenberger S, Schwichtenberg A, Delp E, Rayz V Ann Biomed Eng. 2024; 53(2):331-347.
PMID: 39223318 DOI: 10.1007/s10439-024-03606-w.
Vardhan M, Randles A Biophys Rev (Melville). 2024; 2(1):011302.
PMID: 38505399 PMC: 10903374. DOI: 10.1063/5.0040315.
Bracamonte J, Saunders S, Wilson J, Truong U, Soares J Appl Sci (Basel). 2023; 12(8).
PMID: 36911244 PMC: 10004130. DOI: 10.3390/app12083954.
Moradi H, Al-Hourani A, Concilia G, Khoshmanesh F, Nezami F, Needham S Biophys Rev. 2023; 15(1):19-33.
PMID: 36909958 PMC: 9995635. DOI: 10.1007/s12551-022-01040-7.