» Articles » PMID: 31823191

A Systematic Review for the Design of In Vitro Flow Studies of the Carotid Artery Bifurcation

Overview
Publisher Springer
Date 2019 Dec 12
PMID 31823191
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: In vitro blood flow studies in carotid artery bifurcation models may contribute to understanding the influence of hemodynamics on carotid artery disease. However, the design of in vitro blood flow studies involves many steps and selection of imaging techniques, model materials, model design, and flow visualization parameters. Therefore, an overview of the possibilities and guidance for the design process is beneficial for researchers with less experience in flow studies.

Methods: A systematic search to in vitro flow studies in carotid artery bifurcation models aiming at quantification and detailed flow visualization of blood flow dynamics results in inclusion of 42 articles.

Results: Four categories of imaging techniques are distinguished: MRI, optical particle image velocimetry (PIV), ultrasound and miscellaneous techniques. Parameters for flow visualization are categorized into velocity, flow, shear-related, turbulent/disordered flow and other parameters. Model materials and design characteristics vary between study type.

Conclusions: A simplified three-step design process is proposed for better fitting and adequate match with the pertinent research question at hand and as guidance for less experienced flow study researchers. The three consecutive selection steps are: flow parameters, image modality, and model materials and designs. Model materials depend on the chosen imaging technique, whereas choice of flow parameters is independent from imaging technique and is therefore only determined by the goal of the study.

Citing Articles

Rapid Manufacturing Method of Cardiovascular Models for Experimental Flow Analysis.

Fowler J, Robbins A, Gunawan C, Jastram A, Moreno M MethodsX. 2025; 14():103124.

PMID: 39834677 PMC: 11743567. DOI: 10.1016/j.mex.2024.103124.


Fabrication, characterization and numerical validation of a novel thin-wall hydrogel vessel model for cardiovascular research based on a patient-specific stenotic carotid artery bifurcation.

Shiravand A, Richter K, Willmann P, Eulzer P, Lawonn K, Hundertmark A Sci Rep. 2024; 14(1):16301.

PMID: 39009618 PMC: 11251049. DOI: 10.1038/s41598-024-66777-5.


Literature Survey for In-Vivo Reynolds and Womersley Numbers of Various Arteries and Implications for Compliant In-Vitro Modelling.

Williamson P, Docherty P, Jermy M, Steven B Cardiovasc Eng Technol. 2024; 15(4):418-430.

PMID: 38499933 PMC: 11319390. DOI: 10.1007/s13239-024-00723-4.


Development of an in vitro setup for flow studies in a stented carotid artery bifurcation.

Hoving A, Mikhal J, Kuipers H, de Borst G, Slump C Med Biol Eng Comput. 2023; 62(4):1165-1176.

PMID: 38155315 DOI: 10.1007/s11517-023-02977-x.


A review on non-Newtonian fluid models for multi-layered blood rheology in constricted arteries.

Wajihah S, Sankar D Arch Appl Mech. 2023; 93(5):1771-1796.

PMID: 36743075 PMC: 9886544. DOI: 10.1007/s00419-023-02368-6.


References
1.
van Ooij P, Guedon A, Poelma C, Schneiders J, Rutten M, Marquering H . Complex flow patterns in a real-size intracranial aneurysm phantom: phase contrast MRI compared with particle image velocimetry and computational fluid dynamics. NMR Biomed. 2011; 25(1):14-26. DOI: 10.1002/nbm.1706. View

2.
Nemati M, Loozen G, van der Wekken N, van de Belt G, Urbach H, Bhattacharya N . Application of full field optical studies for pulsatile flow in a carotid artery phantom. Biomed Opt Express. 2015; 6(10):4037-50. PMC: 4605061. DOI: 10.1364/BOE.6.004037. View

3.
Napel S, Lee D, Frayne R, Rutt B . Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging. J Magn Reson Imaging. 1992; 2(2):143-53. DOI: 10.1002/jmri.1880020206. View

4.
Kefayati S, Milner J, Holdsworth D, Poepping T . In vitro shear stress measurements using particle image velocimetry in a family of carotid artery models: effect of stenosis severity, plaque eccentricity, and ulceration. PLoS One. 2014; 9(7):e98209. PMC: 4090132. DOI: 10.1371/journal.pone.0098209. View

5.
Elbaz M, Calkoen E, Westenberg J, Lelieveldt B, Roest A, van der Geest R . Vortex flow during early and late left ventricular filling in normal subjects: quantitative characterization using retrospectively-gated 4D flow cardiovascular magnetic resonance and three-dimensional vortex core analysis. J Cardiovasc Magn Reson. 2014; 16:78. PMC: 4177574. DOI: 10.1186/s12968-014-0078-9. View