» Articles » PMID: 26516885

Indoor Heating Drives Water Bacterial Growth and Community Metabolic Profile Changes in Building Tap Pipes During the Winter Season

Overview
Publisher MDPI
Date 2015 Oct 31
PMID 26516885
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

The growth of the bacterial community harbored in indoor drinking water taps is regulated by external environmental factors, such as indoor temperature. However, the effect of indoor heating on bacterial regrowth associated with indoor drinking water taps is poorly understood. In the present work, flow cytometry and community-level sole-carbon-source utilization techniques were combined to explore the effects of indoor heating on water bacterial cell concentrations and community carbon metabolic profiles in building tap pipes during the winter season. The results showed that the temperature of water stagnated overnight ("before") in the indoor water pipes was 15-17 °C, and the water temperature decreased to 4-6 °C after flushing for 10 min ("flushed"). The highest bacterial cell number was observed in water stagnated overnight, and was 5-11 times higher than that of flushed water. Meanwhile, a significantly higher bacterial community metabolic activity (AWCD590nm) was also found in overnight stagnation water samples. The significant "flushed" and "taps" values indicated that the AWCD590nm, and bacterial cell number varied among the taps within the flushed group (p < 0.01). Heatmap fingerprints and principle component analyses (PCA) revealed a significant discrimination bacterial community functional metabolic profiles in the water stagnated overnight and flushed water. Serine, threonine, glucose-phosphate, ketobutyric acid, phenylethylamine, glycerol, putrescine were significantly used by "before" water samples. The results suggested that water stagnated at higher temperature should be treated before drinking because of bacterial regrowth. The data from this work provides useful information on reasonable utilization of drinking water after stagnation in indoor pipes during indoor heating periods.

Citing Articles

Geographical patterns of denitrifying bacterial communities associated with different urban lakes.

Zhang H, Zhao Z, Chen S, Wang Y, Feng J, Jia J RSC Adv. 2022; 8(31):17079-17090.

PMID: 35539271 PMC: 9080392. DOI: 10.1039/c8ra01295d.


Legionella and other opportunistic pathogens in full-scale chloraminated municipal drinking water distribution systems.

Zhang C, Struewing I, Mistry J, Wahman D, Pressman J, Lu J Water Res. 2021; 205:117571.

PMID: 34628111 PMC: 8629321. DOI: 10.1016/j.watres.2021.117571.


Metabolic Functional Community Diversity of Associated Bacteria during the Degradation of Phytoplankton from a Drinking Water Reservoir.

Chen S, Shang P, Kang P, Du M Int J Environ Res Public Health. 2020; 17(5).

PMID: 32150960 PMC: 7084786. DOI: 10.3390/ijerph17051687.


Geographical Patterns of Algal Communities Associated with Different Urban Lakes in China.

Chen S, He H, Zong R, Liu K, Yan M, Xu L Int J Environ Res Public Health. 2020; 17(3).

PMID: 32033450 PMC: 7037785. DOI: 10.3390/ijerph17031009.


Water quality characteristics and corrosion potential in blending zones in X city drinking water distribution system.

Zhang H, Wang K, Zhou X, Zhu W, Wang W Environ Monit Assess. 2018; 190(9):524.

PMID: 30116900 DOI: 10.1007/s10661-018-6901-2.


References
1.
Hammes F, Berney M, Wang Y, Vital M, Koster O, Egli T . Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes. Water Res. 2007; 42(1-2):269-77. DOI: 10.1016/j.watres.2007.07.009. View

2.
Nescerecka A, Rubulis J, Vital M, Juhna T, Hammes F . Biological instability in a chlorinated drinking water distribution network. PLoS One. 2014; 9(5):e96354. PMC: 4010465. DOI: 10.1371/journal.pone.0096354. View

3.
Herrmann S, Kleinsteuber S, Chatzinotas A, Kuppardt S, Lueders T, Richnow H . Functional characterization of an anaerobic benzene-degrading enrichment culture by DNA stable isotope probing. Environ Microbiol. 2009; 12(2):401-11. DOI: 10.1111/j.1462-2920.2009.02077.x. View

4.
Sun W, Sun X, Cupples A . Anaerobic methyl tert-butyl ether-degrading microorganisms identified in wastewater treatment plant samples by stable isotope probing. Appl Environ Microbiol. 2012; 78(8):2973-80. PMC: 3318814. DOI: 10.1128/AEM.07253-11. View

5.
Heinrichs G, Hubner I, Schmidt C, de Hoog G, Haase G . Analysis of black fungal biofilms occurring at domestic water taps. II: potential routes of entry. Mycopathologia. 2013; 175(5-6):399-412. DOI: 10.1007/s11046-013-9619-2. View