» Articles » PMID: 26469756

Low-Cost High-Performance MRI

Overview
Journal Sci Rep
Specialty Science
Date 2015 Oct 16
PMID 26469756
Citations 93
Authors
Affiliations
Soon will be listed here.
Abstract

Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5-3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site, and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm(3) imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (<10 mT) will complement traditional MRI, providing clinically relevant images and setting new standards for affordable (<$50,000) and robust portable devices.

Citing Articles

Initial insights into post-contrast enhancement in ultra-low-field MRI: Case Report.

Altaf A, Alam M, Khan S, Azan A, Mubarak F, Knopp E Front Neuroimaging. 2025; 4:1507522.

PMID: 40070486 PMC: 11893822. DOI: 10.3389/fnimg.2025.1507522.


Tips and challenges for clinical use and interpretation of low field portable MRI in neuroimaging.

Chen Y, Mathur S, Lin A, Knopp E, Rosen M, Bharatha A Emerg Radiol. 2025; .

PMID: 39976637 DOI: 10.1007/s10140-025-02323-8.


Feasibility and Usability of Low-Field Magnetic Resonance Imaging for Pediatric Neuroimaging in Low- and Middle-Income Countries: A Qualitative Study.

Rowand E, Owusu R, Sibole A, Abu-Haydar E, Delarosa J Med Devices (Auckl). 2025; 18:107-121.

PMID: 39967747 PMC: 11834662. DOI: 10.2147/MDER.S478864.


Portable Accessible MRI in Dementia Research: Ethical Considerations About Research Representation and Dementia-Friendly Technology.

Klein E, Han S, Tuite P, Kimberly W, Agarwal M J Law Med Ethics. 2025; 52(4):830-839.

PMID: 39885747 PMC: 11798667. DOI: 10.1017/jme.2024.157.


Structural MRI of brain similarity networks.

Sebenius I, Dorfschmidt L, Seidlitz J, Alexander-Bloch A, Morgan S, Bullmore E Nat Rev Neurosci. 2024; 26(1):42-59.

PMID: 39609622 DOI: 10.1038/s41583-024-00882-2.


References
1.
Pruessmann K, Weiger M, Scheidegger M, Boesiger P . SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999; 42(5):952-62. View

2.
Scheffler K, Heid O, Hennig J . Magnetization preparation during the steady state: fat-saturated 3D TrueFISP. Magn Reson Med. 2001; 45(6):1075-80. DOI: 10.1002/mrm.1142. View

3.
Plein S, Bloomer T, Ridgway J, Jones T, Bainbridge G, Sivananthan M . Steady-state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging. 2001; 14(3):230-6. DOI: 10.1002/jmri.1178. View

4.
Deshpande V, Shea S, Laub G, Simonetti O, Finn J, Li D . 3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries. Magn Reson Med. 2001; 46(3):494-502. DOI: 10.1002/mrm.1219. View

5.
Griswold M, Jakob P, Heidemann R, Nittka M, Jellus V, Wang J . Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002; 47(6):1202-10. DOI: 10.1002/mrm.10171. View