[Research on a Portable Shielding-free Ultra-low Field Magnetic Resonance Imaging System]

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

The portable light-weight magnetic resonance imaging system can be deployed in special occasions such as Intensive Care Unit (ICU) and ambulances, making it possible to implement bedside monitoring imaging systems, mobile stroke units and magnetic resonance platforms in remote areas. Compared with medium and high field imaging systems, ultra-low-field magnetic resonance imaging equipment utilizes light-weight permanent magnets, which are compact and easy to move. However, the image quality is highly susceptible to external electromagnetic interference without a shielded room and there are still many key technical problems in hardware design to be solved. In this paper, the system hardware design and environmental electromagnetic interference elimination algorithm were studied. Consequently, some research results were obtained and a prototype of portable shielding-free 50 mT magnetic resonance imaging system was built. The light-weight magnet and its uniformity, coil system and noise elimination algorithm and human brain imaging were verified. Finally, high-quality images of the healthy human brain were obtained. The results of this study would provide reference for the development and application of ultra-low-field magnetic resonance imaging technology.

References
1.
Liu Y, Leong A, Zhao Y, Xiao L, Mak H, Tsang A . A low-cost and shielding-free ultra-low-field brain MRI scanner. Nat Commun. 2021; 12(1):7238. PMC: 8671508. DOI: 10.1038/s41467-021-27317-1. View

2.
Su J, Pellicer-Guridi R, Edwards T, Fuentes M, Rosen M, Vegh V . A CNN Based Software Gradiometer for Electromagnetic Background Noise Reduction in Low Field MRI Applications. IEEE Trans Med Imaging. 2022; 41(5):1007-1016. DOI: 10.1109/TMI.2022.3147450. View

3.
Marble A, Mastikhin I, Colpitts B, Balcom B . A constant gradient unilateral magnet for near-surface MRI profiling. J Magn Reson. 2006; 183(2):228-34. DOI: 10.1016/j.jmr.2006.08.013. View

4.
Wang C, Qin X, Liu Y, Zhang W . [Application of an Adaptive Inertia Weight Particle Swarm Algorithm in the Magnetic Resonance Bias Field Correction]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2018; 33(3):564-9. View

5.
Shen S, Xu Z, Koonjoo N, Rosen M . Optimization of a Close-Fitting Volume RF Coil for Brain Imaging at 6.5 mT Using Linear Programming. IEEE Trans Biomed Eng. 2020; 68(4):1106-1114. DOI: 10.1109/TBME.2020.3002077. View