» Articles » PMID: 12928954

Principles and Applications of Balanced SSFP Techniques

Overview
Journal Eur Radiol
Specialty Radiology
Date 2003 Aug 21
PMID 12928954
Citations 229
Authors
Affiliations
Soon will be listed here.
Abstract

During the past 5 years balanced steady-state free precession (SSFP) has become increasingly important for diagnostic and functional imaging. Balanced SSFP is characterized by two unique features: it offers a very high signal-to noise ratio and a T2/T1-weighted image contrast. This article focuses on the physical principles, on the signal formation, and on the resulting properties of balanced SSFP. Mechanisms for contrast modification, recent clinical application, and potential extensions of this technique are discussed.

Citing Articles

Balanced steady state free precession enables high-resolution dynamic 3D Deuterium Metabolic Imaging of the human brain at 7T.

Frese S, Strasser B, Hingerl L, Montrazi E, Frydman L, Motyka S medRxiv. 2025; .

PMID: 39974047 PMC: 11838661. DOI: 10.1101/2025.02.06.25321580.


Unlocking the Potential of Chest MRI: Strategies for Establishing a Successful Practice.

Kim K, Kim K, Lee J, Jeong Y J Korean Soc Radiol. 2025; 86(1):83-104.

PMID: 39958489 PMC: 11822286. DOI: 10.3348/jksr.2024.0056.


Ventricular function assessment using an ultrafast spoiled gradient echo sequence with an intravascular blood pool contrast agent in pediatric patients.

Miah T, Gunda R, Greil G, Hussain M, Zou Q PLoS One. 2025; 20(1):e0318299.

PMID: 39888889 PMC: 11785336. DOI: 10.1371/journal.pone.0318299.


Elucidating hemodynamics and neuro-glio-vascular signaling using rodent fMRI.

Zhou X, Jiang Y, Gomez-Cid L, Yu X Trends Neurosci. 2025; 48(3):227-241.

PMID: 39843335 PMC: 11903151. DOI: 10.1016/j.tins.2024.12.010.


Automatic Adaptive Algorithm for Delineation of Cerebral-Spinal Fluid Regions for Non-contrast Magnetic Resonance Imaging Volumetry and Cisternography in Mice.

Gomolka R Bio Protoc. 2025; 15(1):e5148.

PMID: 39803313 PMC: 11717714. DOI: 10.21769/BioProtoc.5148.


References
1.
Hennig J, Speck O, Scheffler K . Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences. Magn Reson Med. 2002; 48(5):801-9. DOI: 10.1002/mrm.10274. View

2.
Norris D, Bornert P, Reese T, Leibfritz D . On the application of ultra-fast RARE experiments. Magn Reson Med. 1992; 27(1):142-64. DOI: 10.1002/mrm.1910270114. View

3.
Overall W, Conolly S, Nishimura D, Hu B . Oscillating dual-equilibrium steady-state angiography. Magn Reson Med. 2002; 47(3):513-22. DOI: 10.1002/mrm.10070. View

4.
Hargreaves B, Vasanawala S, Pauly J, Nishimura D . Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med. 2001; 46(1):149-58. DOI: 10.1002/mrm.1170. View

5.
Scheffler K, Hennig J . T(1) quantification with inversion recovery TrueFISP. Magn Reson Med. 2001; 45(4):720-3. DOI: 10.1002/mrm.1097. View