» Articles » PMID: 26466113

Improved Semiautomated 4D Flow MRI Analysis in the Aorta in Patients With Congenital Aortic Valve Anomalies Versus Tricuspid Aortic Valves

Overview
Specialty Radiology
Date 2015 Oct 15
PMID 26466113
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The aim of this study was to systematically investigate a newly developed semiautomated workflow for the analysis of aortic 4-dimensional flow MRI and its ability to detect hemodynamic differences in patients with congenitally altered aortic valve (bicuspid or quadricuspid valves) compared with tricuspid aortic valves.

Methods: Four-dimensional flow MRI data were acquired in 20 patients with aortic dilatation (9 tricuspid aortic valves, 11 congenitally altered aortic valves). A semiautomated workflow was evaluated regarding interobserver variability, accuracy of net flow, regurgitant fraction and peak systolic velocity, and the ability to detect differences between cohorts. Results were compared with manual segmentation of vessel contours.

Results: Despite the significantly reduced analysis time, a good interobserver agreement was found for net flow and peak systolic velocity, and a moderate agreement was found for regurgitation. Significant differences in peak velocities in the descending aorta (P = 0.014) could be detected.

Conclusions: Four-dimensional flow MRI-based semiautomated analysis of aortic hemodynamics can be performed with good reproducibility and accuracy.

Citing Articles

Differences in Pulmonary Artery Flow Hemodynamics Between PAH and PH-HFpEF: Insights From 4D-Flow CMR.

Kim B, Lee J, Berhane H, Freed B, Shah S, Thomas J Pulm Circ. 2025; 15(1):e70022.

PMID: 39749111 PMC: 11693845. DOI: 10.1002/pul2.70022.


Using Gaussian process for velocity reconstruction after coronary stenosis applicable in positron emission particle tracking: An in-silico study.

Keramati H, de Vecchi A, Rajani R, Niederer S PLoS One. 2023; 18(12):e0295789.

PMID: 38096169 PMC: 10721050. DOI: 10.1371/journal.pone.0295789.


Quantifying 4D flow cardiovascular magnetic resonance vortices in patients with pulmonary hypertension: A pilot study.

Borhani A, Porter K, Umair M, Chu L, Mathai S, Kolb T Pulm Circ. 2023; 13(4):e12298.

PMID: 37859803 PMC: 10583650. DOI: 10.1002/pul2.12298.


Changes of aortic hemodynamics after aortic valve replacement-A four dimensional flow cardiovascular magnetic resonance follow up study.

Wiesemann S, Trauzeddel R, Musa A, Hickstein R, Mayr T, von Knobelsdorff-Brenkenhoff F Front Cardiovasc Med. 2023; 10:1071643.

PMID: 36865891 PMC: 9971963. DOI: 10.3389/fcvm.2023.1071643.


The role of 4-dimensional flow in the assessment of bicuspid aortic valve and its valvulo-aortopathies.

Richards C, Parker A, Alfuhied A, McCann G, Singh A Br J Radiol. 2022; 95(1139):20220123.

PMID: 35852109 PMC: 9793489. DOI: 10.1259/bjr.20220123.


References
1.
Eriksson J, Carlhall C, Dyverfeldt P, Engvall J, Bolger A, Ebbers T . Semi-automatic quantification of 4D left ventricular blood flow. J Cardiovasc Magn Reson. 2010; 12:9. PMC: 2831022. DOI: 10.1186/1532-429X-12-9. View

2.
Hiratzka L, Bakris G, Beckman J, Bersin R, Carr V, Casey Jr D . 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the diagnosis and management of patients with thoracic aortic disease. A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice.... J Am Coll Cardiol. 2010; 55(14):e27-e129. DOI: 10.1016/j.jacc.2010.02.015. View

3.
Valverde I, Simpson J, Schaeffter T, Beerbaum P . 4D phase-contrast flow cardiovascular magnetic resonance: comprehensive quantification and visualization of flow dynamics in atrial septal defect and partial anomalous pulmonary venous return. Pediatr Cardiol. 2010; 31(8):1244-8. DOI: 10.1007/s00246-010-9782-x. View

4.
Markl M, Wallis W, Harloff A . Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI. J Magn Reson Imaging. 2011; 33(4):988-94. DOI: 10.1002/jmri.22519. View

5.
Hope M, Hope T, Crook S, Ordovas K, Urbania T, Alley M . 4D flow CMR in assessment of valve-related ascending aortic disease. JACC Cardiovasc Imaging. 2011; 4(7):781-7. DOI: 10.1016/j.jcmg.2011.05.004. View