» Articles » PMID: 26380089

Immune Monitoring Technology Primer: Flow and Mass Cytometry

Overview
Date 2015 Sep 18
PMID 26380089
Citations 18
Authors
Affiliations
Soon will be listed here.
Citing Articles

Signal amplification by cyclic extension enables high-sensitivity single-cell mass cytometry.

Lun X, Sheng K, Yu X, Lam C, Gowri G, Serrata M Nat Biotechnol. 2024; .

PMID: 39075149 DOI: 10.1038/s41587-024-02316-x.


Spectral Flow Cytometry Methods and Pipelines for Comprehensive Immunoprofiling of Human Peripheral Blood and Bone Marrow.

Spasic M, Ogayo E, Parsons A, Mittendorf E, van Galen P, McAllister S Cancer Res Commun. 2024; 4(3):895-910.

PMID: 38466569 PMC: 10962315. DOI: 10.1158/2767-9764.CRC-23-0357.


Performance of spectral flow cytometry and mass cytometry for the study of innate myeloid cell populations.

van der Pan K, Khatri I, de Jager A, Louis A, Kassem S, Naber B Front Immunol. 2023; 14:1191992.

PMID: 37275858 PMC: 10235610. DOI: 10.3389/fimmu.2023.1191992.


Full spectrum flow cytometry and mass cytometry: A 32-marker panel comparison.

Jaimes M, Leipold M, Kraker G, Amir E, Maecker H, Lannigan J Cytometry A. 2022; 101(11):942-959.

PMID: 35593221 PMC: 9790709. DOI: 10.1002/cyto.a.24565.


Simplified mass cytometry protocol for in-plate staining, barcoding, and cryopreservation of human PBMC samples in clinical trials.

Abrecht C, Hallisey M, Dennis J, Nazzaro M, Brainard M, Hathaway E STAR Protoc. 2022; 3(2):101362.

PMID: 35573480 PMC: 9092992. DOI: 10.1016/j.xpro.2022.101362.


References
1.
Chester C, Maecker H . Algorithmic Tools for Mining High-Dimensional Cytometry Data. J Immunol. 2015; 195(3):773-9. PMC: 4507289. DOI: 10.4049/jimmunol.1500633. View

2.
Aghaeepour N, Finak G, Hoos H, Mosmann T, Brinkman R, Gottardo R . Critical assessment of automated flow cytometry data analysis techniques. Nat Methods. 2013; 10(3):228-38. PMC: 3906045. DOI: 10.1038/nmeth.2365. View

3.
Qiu P, Simonds E, Bendall S, Gibbs Jr K, Bruggner R, Linderman M . Extracting a cellular hierarchy from high-dimensional cytometry data with SPADE. Nat Biotechnol. 2011; 29(10):886-91. PMC: 3196363. DOI: 10.1038/nbt.1991. View

4.
Mei H, Leipold M, Schulz A, Chester C, Maecker H . Barcoding of live human peripheral blood mononuclear cells for multiplexed mass cytometry. J Immunol. 2015; 194(4):2022-31. PMC: 4323739. DOI: 10.4049/jimmunol.1402661. View

5.
Ornatsky O, Bandura D, Baranov V, Nitz M, Winnik M, Tanner S . Highly multiparametric analysis by mass cytometry. J Immunol Methods. 2010; 361(1-2):1-20. DOI: 10.1016/j.jim.2010.07.002. View