» Articles » PMID: 26158055

Quantitative Simultaneous Positron Emission Tomography and Magnetic Resonance Imaging

Overview
Specialty Radiology
Date 2015 Jul 10
PMID 26158055
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Simultaneous positron emission tomography and magnetic resonance imaging (PET-MR) is an innovative and promising imaging modality that is generating substantial interest in the medical imaging community, while offering many challenges and opportunities. In this study, we investigated whether MR surface coils need to be accounted for in PET attenuation correction. Furthermore, we integrated motion correction, attenuation correction, and point spread function modeling into a single PET reconstruction framework. We applied our reconstruction framework to in vivo animal and patient PET-MR studies. We have demonstrated that our approach greatly improved PET image quality.

Citing Articles

Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Polycarpou I, Soultanidis G, Tsoumpas C Philos Trans A Math Phys Eng Sci. 2021; 379(2204):20200207.

PMID: 34218675 PMC: 8255946. DOI: 10.1098/rsta.2020.0207.


Assessment of a novel 32-channel phased array for cardiovascular hybrid PET/MRI imaging: MRI performance.

Farag A, Thompson R, Thiessen J, Butler J, Prato F, Theberge J Eur J Hybrid Imaging. 2020; 3(1):13.

PMID: 33283144 PMC: 7717874. DOI: 10.1186/s41824-019-0061-7.


Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

Rakvongthai Y, El Fakhri G PET Clin. 2017; 12(3):321-327.

PMID: 28576170 PMC: 6452624. DOI: 10.1016/j.cpet.2017.02.004.


Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies.

Petibon Y, Rakvongthai Y, El Fakhri G, Ouyang J Phys Med Biol. 2017; 62(9):3539-3565.

PMID: 28379843 PMC: 5739089. DOI: 10.1088/1361-6560/aa6394.


Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR.

Petibon Y, Guehl N, Reese T, Ebrahimi B, Normandin M, Shoup T Phys Med Biol. 2016; 62(2):326-343.

PMID: 27997375 PMC: 5241952. DOI: 10.1088/1361-6560/aa5087.


References
1.
Zaidi H, Montandon M, Slosman D . Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. Med Phys. 2003; 30(5):937-48. DOI: 10.1118/1.1569270. View

2.
Salomon A, Goedicke A, Schweizer B, Aach T, Schulz V . Simultaneous reconstruction of activity and attenuation for PET/MR. IEEE Trans Med Imaging. 2010; 30(3):804-13. DOI: 10.1109/TMI.2010.2095464. View

3.
Catana C, van der Kouwe A, Benner T, Michel C, Hamm M, Fenchel M . Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med. 2010; 51(9):1431-8. PMC: 3801218. DOI: 10.2967/jnumed.109.069112. View

4.
Geworski L, Knoop B, de Cabrejas M, Knapp W, Munz D . Recovery correction for quantitation in emission tomography: a feasibility study. Eur J Nucl Med. 2001; 27(2):161-9. DOI: 10.1007/s002590050022. View

5.
Keereman V, Van Holen R, Mollet P, Vandenberghe S . The effect of errors in segmented attenuation maps on PET quantification. Med Phys. 2011; 38(11):6010-9. DOI: 10.1118/1.3651640. View