Abstract

Subject motion in positron emission tomography (PET) is a key factor that degrades image resolution and quality, limiting its potential capabilities. Correcting for it is complicated due to the lack of sufficient measured PET data from each position. This poses a significant barrier in calculating the amount of motion occurring during a scan. Motion correction can be implemented at different stages of data processing either during or after image reconstruction, and once applied accurately can substantially improve image quality and information accuracy. With the development of integrated PET-MRI (magnetic resonance imaging) scanners, internal organ motion can be measured concurrently with both PET and MRI. In this review paper, we explore the synergistic use of PET and MRI data to correct for any motion that affects the PET images. Different types of motion that can occur during PET-MRI acquisitions are presented and the associated motion detection, estimation and correction methods are reviewed. Finally, some highlights from recent literature in selected human and animal imaging applications are presented and the importance of motion correction for accurate kinetic modelling in dynamic PET-MRI is emphasized. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 2'.

Citing Articles

Development of quantitative PET/MR imaging for measurements of hepatic portal vein input function: a phantom study.

Chalampalakis Z, Ortner M, Almuttairi M, Bauer M, Tamm E, Schmidt A EJNMMI Phys. 2024; 11(1):90.

PMID: 39489802 PMC: 11532313. DOI: 10.1186/s40658-024-00694-4.


Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System.

Kang F, Xie Z, Ma W, Quan Z, Li G, Guo K J Nucl Med. 2024; 65(8):1313-1319.

PMID: 38991753 PMC: 11294066. DOI: 10.2967/jnumed.124.267446.


Application of PET/MRI in Gynecologic Malignancies.

Ebrahimi S, Lundstrom E, Batasin S, Hedlund E, Stalberg K, Ehman E Cancers (Basel). 2024; 16(8).

PMID: 38672560 PMC: 11048306. DOI: 10.3390/cancers16081478.


The clinical value of quantitative cardiovascular molecular imaging: a step towards precision medicine.

Tingen H, van Praagh G, Nienhuis P, Tubben A, van Rijsewijk N, Ten Hove D Br J Radiol. 2023; 96(1152):20230704.

PMID: 37786997 PMC: 10646628. DOI: 10.1259/bjr.20230704.


Skin Cancer Pathobiology at a Glance: A Focus on Imaging Techniques and Their Potential for Improved Diagnosis and Surveillance in Clinical Cohorts.

Dobre E, Surcel M, Constantin C, Ilie M, Caruntu A, Caruntu C Int J Mol Sci. 2023; 24(2).

PMID: 36674595 PMC: 9866322. DOI: 10.3390/ijms24021079.


References
1.
Marchesseau S, Totman J, Fadil H, Leek F, Chaal J, Richards M . Cardiac motion and spillover correction for quantitative PET imaging using dynamic MRI. Med Phys. 2018; 46(2):726-737. DOI: 10.1002/mp.13345. View

2.
Kustner T, Armanious K, Yang J, Yang B, Schick F, Gatidis S . Retrospective correction of motion-affected MR images using deep learning frameworks. Magn Reson Med. 2019; 82(4):1527-1540. DOI: 10.1002/mrm.27783. View

3.
King A, Buerger C, Tsoumpas C, Marsden P, Schaeffter T . Thoracic respiratory motion estimation from MRI using a statistical model and a 2-D image navigator. Med Image Anal. 2011; 16(1):252-64. DOI: 10.1016/j.media.2011.08.003. View

4.
Kolbitsch C, Neji R, Fenchel M, Schuh A, Mallia A, Marsden P . Joint cardiac and respiratory motion estimation for motion-corrected cardiac PET-MR. Phys Med Biol. 2018; 64(1):015007. DOI: 10.1088/1361-6560/aaf246. View

5.
Heiba S, Raphael B, Castellon I, Altinyay E, Sandella N, Rosen G . PET/CT image fusion error due to urinary bladder filling changes: consequence and correction. Ann Nucl Med. 2009; 23(8):739-44. DOI: 10.1007/s12149-009-0304-y. View