» Articles » PMID: 25979022

A Dual-Kinect Approach to Determine Torso Surface Motion for Respiratory Motion Correction in PET

Overview
Journal Med Phys
Specialty Biophysics
Date 2015 May 17
PMID 25979022
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness-including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches.

Methods: The data of two Kinects are used to calculate 3D representations of a patient's torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method's suitability for providing meaningful data. In addition, the authors employed it during clinical (18)F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences.

Results: The authors' results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was found to be stronger with abdominal signals than with thoracic signals (average Pearson correlation coefficients of 0.74 ± 0.17 and 0.45 ± 0.23, respectively). In all cases, except one, the abdominal respiratory motion preceded the thoracic motion-a maximum delay of approximately 600 ms was detected.

Conclusions: The method provides motion information with sufficiently high spatial and temporal resolution. Thus, it enables meaningful analysis in the form of comparisons between amplitudes and phase shifts of signals from different regions. In combination with a large field-of-view, as given by combining the data of two Kinect cameras, it yields surface representations that might be useful in the context of motion correction and motion modeling.

Citing Articles

Motion-correction strategies for enhancing whole-body PET imaging.

Wang J, Bermudez D, Chen W, Durgavarjhula D, Randell C, Uyanik M Front Nucl Med. 2024; 4.

PMID: 39118964 PMC: 11308502. DOI: 10.3389/fnume.2024.1257880.


3D Kinect Camera Scheme with Time-Series Deep-Learning Algorithms for Classification and Prediction of Lung Tumor Motility.

Puangragsa U, Setakornnukul J, Dankulchai P, Phasukkit P Sensors (Basel). 2022; 22(8).

PMID: 35458903 PMC: 9024525. DOI: 10.3390/s22082918.


Development and accuracy evaluation of a single-camera intra-bore surface scanning system for radiotherapy in an O-ring linac.

Delombaerde L, Petillion S, Michiels S, Weltens C, Depuydt T Phys Imaging Radiat Oncol. 2021; 11:21-26.

PMID: 33458272 PMC: 7807582. DOI: 10.1016/j.phro.2019.07.003.


Advancements in Methods and Camera-Based Sensors for the Quantification of Respiration.

Rehouma H, Noumeir R, Essouri S, Jouvet P Sensors (Basel). 2020; 20(24).

PMID: 33348827 PMC: 7766256. DOI: 10.3390/s20247252.


Recent advanced in Surface Guided Radiation Therapy.

Freislederer P, Kugele M, Ollers M, Swinnen A, Sauer T, Bert C Radiat Oncol. 2020; 15(1):187.

PMID: 32736570 PMC: 7393906. DOI: 10.1186/s13014-020-01629-w.