» Articles » PMID: 28111534

Evaluation of Kinect 3D Sensor for Healthcare Imaging

Overview
Journal J Med Biol Eng
Date 2017 Jan 24
PMID 28111534
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Microsoft Kinect is a three-dimensional (3D) sensor originally designed for gaming that has received growing interest as a cost-effective and safe device for healthcare imaging. Recent applications of Kinect in health monitoring, screening, rehabilitation, assistance systems, and intervention support are reviewed here. The suitability of available technologies for healthcare imaging applications is assessed. The performance of Kinect I, based on structured light technology, is compared with that of the more recent Kinect II, which uses time-of-flight measurement, under conditions relevant to healthcare applications. The accuracy, precision, and resolution of 3D images generated with Kinect I and Kinect II are evaluated using flat cardboard models representing different skin colors (pale, medium, and dark) at distances ranging from 0.5 to 1.2 m and measurement angles of up to 75°. Both sensors demonstrated high accuracy (majority of measurements <2 mm) and precision (mean point to plane error <2 mm) at an average resolution of at least 390 points per cm. Kinect I is capable of imaging at shorter measurement distances, but Kinect II enables structures angled at over 60° to be evaluated. Kinect II showed significantly higher precision and Kinect I showed significantly higher resolution (both  < 0.001). The choice of object color can influence measurement range and precision. Although Kinect is not a medical imaging device, both sensor generations show performance adequate for a range of healthcare imaging applications. Kinect I is more appropriate for short-range imaging and Kinect II is more appropriate for imaging highly curved surfaces such as the face or breast.

Citing Articles

Factors affecting augmented reality head-mounted device performance in real OR.

Suter D, Hodel S, Liebmann F, Furnstahl P, Farshad M Eur Spine J. 2023; 32(10):3425-3433.

PMID: 37552327 DOI: 10.1007/s00586-023-07826-x.


A Low-Cost Foot-Placed UWB and IMU Fusion-Based Indoor Pedestrian Tracking System for IoT Applications.

Naheem K, Kim M Sensors (Basel). 2022; 22(21).

PMID: 36365858 PMC: 9657577. DOI: 10.3390/s22218160.


Validity of sagittal thoracolumbar curvature measurement using a non-radiographic surface topography method.

Hannink E, Dawes H, Shannon T, Barker K Spine Deform. 2022; 10(6):1299-1306.

PMID: 35809201 PMC: 9579080. DOI: 10.1007/s43390-022-00538-0.


Comparison of Motion Analysis Systems in Tracking Upper Body Movement of Myoelectric Bypass Prosthesis Users.

Wang S, Civillico G, Niswander W, Kontson K Sensors (Basel). 2022; 22(8).

PMID: 35458943 PMC: 9029489. DOI: 10.3390/s22082953.


KinectGaitNet: Kinect-Based Gait Recognition Using Deep Convolutional Neural Network.

Bari A, Gavrilova M Sensors (Basel). 2022; 22(7).

PMID: 35408243 PMC: 9002886. DOI: 10.3390/s22072631.


References
1.
Gritsenko V, Dailey E, Kyle N, Taylor M, Whittacre S, Swisher A . Feasibility of Using Low-Cost Motion Capture for Automated Screening of Shoulder Motion Limitation after Breast Cancer Surgery. PLoS One. 2015; 10(6):e0128809. PMC: 4468119. DOI: 10.1371/journal.pone.0128809. View

2.
Kosse N, Brands K, Bauer J, Hortobagyi T, Lamoth C . Sensor technologies aiming at fall prevention in institutionalized old adults: a synthesis of current knowledge. Int J Med Inform. 2013; 82(9):743-52. DOI: 10.1016/j.ijmedinf.2013.06.001. View

3.
Nouei M, Kamyad A, Soroush A, Ghazalbash S . A comprehensive operating room information system using the Kinect sensors and RFID. J Clin Monit Comput. 2014; 29(2):251-61. DOI: 10.1007/s10877-014-9591-5. View

4.
Henseler H, Kuznetsova A, Vogt P, Rosenhahn B . Validation of the Kinect device as a new portable imaging system for three-dimensional breast assessment. J Plast Reconstr Aesthet Surg. 2014; 67(4):483-8. DOI: 10.1016/j.bjps.2013.12.025. View

5.
Ejupi A, Brodie M, Gschwind Y, Lord S, Zagler W, Delbaere K . Kinect-Based Five-Times-Sit-to-Stand Test for Clinical and In-Home Assessment of Fall Risk in Older People. Gerontology. 2015; 62(1):118-24. DOI: 10.1159/000381804. View