» Articles » PMID: 25621491

On the Subjective Acceptance During Cardiovascular Magnetic Resonance Imaging at 7.0 Tesla

Abstract

Purpose: This study examines the subjective acceptance during UHF-CMR in a cohort of healthy volunteers who underwent a cardiac MR examination at 7.0T.

Methods: Within a period of two-and-a-half years (January 2012 to June 2014) a total of 165 healthy volunteers (41 female, 124 male) without any known history of cardiac disease underwent UHF-CMR. For the assessment of the subjective acceptance a questionnaire was used to examine the participants experience prior, during and after the UHF-CMR examination. For this purpose, subjects were asked to respond to the questionnaire in an exit interview held immediately after the completion of the UHF-CMR examination under supervision of a study nurse to ensure accurate understanding of the questions. All questions were answered with "yes" or "no" including space for additional comments.

Results: Transient muscular contraction was documented in 12.7% of the questionnaires. Muscular contraction was reported to occur only during periods of scanning with the magnetic field gradients being rapidly switched. Dizziness during the study was reported by 12.7% of the subjects. Taste of metal was reported by 10.1% of the study population. Light flashes were reported by 3.6% of the entire cohort. 13% of the subjects reported side effects/observations which were not explicitly listed in the questionnaire but covered by the question about other side effects. No severe side effects as vomiting or syncope after scanning occurred. No increase in heart rate was observed during the UHF-CMR exam versus the baseline clinical examination.

Conclusions: This study adds to the literature by detailing the subjective acceptance of cardiovascular magnetic resonance imaging examinations at a magnetic field strength of 7.0T. Cardiac MR examinations at 7.0T are well tolerated by healthy subjects. Broader observational and multi-center studies including patient cohorts with cardiac diseases are required to gain further insights into the subjective acceptance of UHF-CMR examinations.

Citing Articles

Patient Comfort in Modern Computed Tomography: What Really Counts.

Niehoff J, Heuser A, Michael A, Lennartz S, Borggrefe J, Kroeger J Tomography. 2022; 8(3):1401-1412.

PMID: 35645399 PMC: 9149918. DOI: 10.3390/tomography8030113.


On the way to routine cardiac MRI at 7 Tesla - a pilot study on consecutive 84 examinations.

Reiter T, Lohr D, Hock M, Ankenbrand M, Stefanescu M, Kosmala A PLoS One. 2021; 16(7):e0252797.

PMID: 34297720 PMC: 8301632. DOI: 10.1371/journal.pone.0252797.


Cardiac functional magnetic resonance imaging at 7T: Image quality optimization and ultra-high field capabilities.

Ibrahim E, Arpinar V, Tugan Muftuler L, Stojanovska J, Nencka A, Koch K World J Radiol. 2020; 12(10):231-246.

PMID: 33240463 PMC: 7653183. DOI: 10.4329/wjr.v12.i10.231.


Controlled Release of Therapeutics from Thermoresponsive Nanogels: A Thermal Magnetic Resonance Feasibility Study.

Ji Y, Winter L, Navarro L, Ku M, Periquito J, Pham M Cancers (Basel). 2020; 12(6).

PMID: 32471299 PMC: 7352924. DOI: 10.3390/cancers12061380.


High Spatial Resolution Cardiovascular Magnetic Resonance at 7.0 Tesla in Patients with Hypertrophic Cardiomyopathy - First Experiences: Lesson Learned from 7.0 Tesla.

Prothmann M, von Knobelsdorff-Brenkenhoff F, Topper A, Dieringer M, Shahid E, Graessl A PLoS One. 2016; 11(2):e0148066.

PMID: 26863618 PMC: 4749213. DOI: 10.1371/journal.pone.0148066.


References
1.
Rodgers C, Clarke W, Snyder C, Thomas Vaughan J, Neubauer S, Robson M . Human cardiac 31P magnetic resonance spectroscopy at 7 Tesla. Magn Reson Med. 2013; 72(2):304-15. PMC: 4106879. DOI: 10.1002/mrm.24922. View

2.
Kramer C, Barkhausen J, Flamm S, Kim R, Nagel E . Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update. J Cardiovasc Magn Reson. 2013; 15:91. PMC: 3851953. DOI: 10.1186/1532-429X-15-91. View

3.
van Elderen S, van Elderen S, Versluis M, Webb A, Westenberg J, Doornbos J . Initial results on in vivo human coronary MR angiography at 7 T. Magn Reson Med. 2009; 62(6):1379-84. DOI: 10.1002/mrm.22168. View

4.
Meloni A, Hezel F, Positano V, Keilberg P, Pepe A, Lombardi M . Detailing magnetic field strength dependence and segmental artifact distribution of myocardial effective transverse relaxation rate at 1.5, 3.0, and 7.0 T. Magn Reson Med. 2013; 71(6):2224-30. DOI: 10.1002/mrm.24856. View

5.
van Elderen S, Versluis M, Westenberg J, Agarwal H, Smith N, Stuber M . Right coronary MR angiography at 7 T: a direct quantitative and qualitative comparison with 3 T in young healthy volunteers. Radiology. 2010; 257(1):254-9. PMC: 2941721. DOI: 10.1148/radiol.100615. View