» Articles » PMID: 25429371

Relative Quantification of Amine-containing Metabolites Using Isobaric N,N-dimethyl Leucine (DiLeu) Reagents Via LC-ESI-MS/MS and CE-ESI-MS/MS

Overview
Journal Analyst
Specialty Chemistry
Date 2014 Nov 28
PMID 25429371
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Tandem mass spectrometry (MS/MS)-based relative quantification by isobaric labeling is a useful technique to compare different metabolic expression levels in biological systems. For the first time, we have labeled primary and secondary amine-containing small molecules using 4-plex isobaric N,N-dimethyl leucine (DiLeu) to perform relative quantification. Good labeling efficiency and quantification accuracy were demonstrated with a mixture of 12 metabolite standards including amino acids and small molecule neurotransmitters. Labeling amine-containing metabolites with DiLeu reagents also enabled the separation of polar metabolites by nanoRPLC and improved the detection sensitivity by CE-ESI-MS. The 4-plex DiLeu labeling technique combined with LC-MS/MS and CE-MS/MS platforms were applied to profile and quantify amine-containing metabolites in mouse urine. The variability of concentrations of identified metabolites in urine samples from different mouse individuals was illustrated by the ratios of reporter ion intensities acquired from online data-dependent analysis.

Citing Articles

High-throughput relative quantification of fatty acids by 12-plex isobaric labeling and microchip capillary electrophoresis - Mass spectrometry.

Wang Z, Li M, Xu S, Sun L, Li L Anal Chim Acta. 2024; 1318:342905.

PMID: 39067909 PMC: 11299455. DOI: 10.1016/j.aca.2024.342905.


Salivary metabolomic identification of biomarker candidates for oral melanoma and oral squamous cell carcinoma in dogs.

Ploypetch S, Luo X, Zhao S, Roytrakul S, Li L, Suriyaphol G J Vet Intern Med. 2024; 38(4):2293-2304.

PMID: 38703129 PMC: 11256132. DOI: 10.1111/jvim.17092.


CHRISTMAS: Chiral Pair Isobaric Labeling Strategy for Multiplexed Absolute Quantitation of Enantiomeric Amino Acids.

Zhu Z, Xu S, Wang Z, Delafield D, Rigby M, Lu G Anal Chem. 2023; 95(50):18504-18513.

PMID: 38033201 PMC: 10872458. DOI: 10.1021/acs.analchem.3c03847.


Separation and Detection of Tyrosine and Phenylalanine-derived Oxidative Stress Biomarkers Using Microchip Electrophoresis with Electrochemical Detection.

Weerasekara D, Lunte S Electroanalysis. 2023; 34(12):1913-1927.

PMID: 37220612 PMC: 10202003. DOI: 10.1002/elan.202100580.


Quantification of Serum Metabolites in Early Colorectal Adenomas Using Isobaric Labeling Mass Spectrometry.

Liu Y, Zhang H, Dove W, Wang Z, Zhu Z, Pickhardt P J Proteome Res. 2023; 22(5):1483-1491.

PMID: 37014956 PMC: 10276621. DOI: 10.1021/acs.jproteome.3c00006.


References
1.
Shortreed M, Lamos S, Frey B, Phillips M, Patel M, Belshaw P . Ionizable isotopic labeling reagent for relative quantification of amine metabolites by mass spectrometry. Anal Chem. 2006; 78(18):6398-403. DOI: 10.1021/ac0607008. View

2.
Knee J, Rzezniczak T, Barsch A, Guo K, Merritt T . A novel ion pairing LC/MS metabolomics protocol for study of a variety of biologically relevant polar metabolites. J Chromatogr B Analyt Technol Biomed Life Sci. 2013; 936:63-73. DOI: 10.1016/j.jchromb.2013.07.027. View

3.
Wang J, Zhang Y, Xiang F, Zhang Z, Li L . Combining capillary electrophoresis matrix-assisted laser desorption/ionization mass spectrometry and stable isotopic labeling techniques for comparative crustacean peptidomics. J Chromatogr A. 2010; 1217(26):4463-70. PMC: 2882495. DOI: 10.1016/j.chroma.2010.02.084. View

4.
Zhong X, Maxwell E, Chen D . Mass transport in a micro flow-through vial of a junction-at-the-tip capillary electrophoresis-mass spectrometry interface. Anal Chem. 2011; 83(12):4916-23. DOI: 10.1021/ac200636y. View

5.
Murphy J, Everley R, Coloff J, Gygi S . Combining amine metabolomics and quantitative proteomics of cancer cells using derivatization with isobaric tags. Anal Chem. 2014; 86(7):3585-93. PMC: 3983006. DOI: 10.1021/ac500153a. View