An interface for CE-ESI-MS that decouples both the electrical and the solution flow rate requirements of the separation and ionization processes is presented. The interface uses a tapered and beveled stainless steel hollow needle surrounding the separation capillary terminus so that the inside of the electrode acts as the CE outlet vial and the outside tip acts as the electrospray emitter. No capillary pre-treatment is required, enabling the use of capillaries with any type of surface modification. A chemical modifier solution is introduced through a second capillary connected to the needle via a tee junction and can be used to improve the compatibility of the CE BGE with electrospray. The flow rate of modifier solution can be as low as 0.1 microL/min, much less than that in a typical sheath-flow interface, thus minimizing dilution of the CE effluent in order to maximize sensitivity. The presence of the modifier solution also allows the use of neutral-coated capillaries for protein analysis by CE-MS without using an assisting pressure, despite the absence of EOF under these conditions. The interface is easily integrated into a commercial CE instrument, such that all operations can be carried out by the automated controls. Compared with a commercial sheath-flow CE-MS interface operating under optimized conditions, LODs for amino acids were, on average, improved fivefold.

Citing Articles

Mass spectrometry-intensive top-down proteomics: an update on technology advancements and biomedical applications.

Xu T, Wang Q, Wang Q, Sun L Anal Methods. 2024; 16(28):4664-4682.

PMID: 38973469 PMC: 11257149. DOI: 10.1039/d4ay00651h.


Capillary Electromigration Techniques Coupled to Mass Spectrometry: Applications to Food Analysis.

Patel V, Shamsi S, Sutherland K Trends Analyt Chem. 2022; 139.

PMID: 36189329 PMC: 9523474. DOI: 10.1016/j.trac.2021.116240.


Nanoflow Sheath Voltage-Free Interfacing of Capillary Electrophoresis and Mass Spectrometry for the Detection of Small Molecules.

Elshamy Y, Strein T, Holland L, Li C, DeBastiani A, Valentine S Anal Chem. 2022; 94(32):11329-11336.

PMID: 35913997 PMC: 9387528. DOI: 10.1021/acs.analchem.2c02074.


Fractionation and characterization of sialyl linkage isomers of serum N-glycans by CE-MS.

Zhou X, Song W, Novotny M, Jacobson S J Sep Sci. 2022; 45(17):3348-3361.

PMID: 35819141 PMC: 9473921. DOI: 10.1002/jssc.202200223.


Capillary Electrophoresis-Mass Spectrometry for Metabolomics: Possibilities and Perspectives.

Drouin N, Ramautar R Adv Exp Med Biol. 2021; 1336:159-178.

PMID: 34628632 DOI: 10.1007/978-3-030-77252-9_9.