Accurate disease diagnosis in animals is crucial for animal well-being but also for preventing zoonosis transmission to humans. In particular, livestock diseases may constitute severe threats to humans due to the particularly high physical contact and exposure and, also, be the cause of important economic losses, even in non-endemic countries, where they often arise in the form of rapid and devastating epidemics. Rapid diagnostic tests have been used for a long time in field situations, particularly during outbreaks. However, they mostly rely on serological approaches, which may confirm the exposure to a particular pathogen but may be inappropriate for point-of-decision (point-of-care) settings when emergency responses supported on early and accurate diagnosis are required. Moreover, they often exhibit modest sensitivity and hence significantly depend on later result confirmation in central or reference laboratories. The impressive advances observed in recent years in materials sciences and in nanotechnology, as well as in nucleic-acid synthesis and engineering, have led to an outburst of new in-the-bench and prototype tests for nucleic-acid testing towards point-of-care diagnosis of genetic and infectious diseases. Manufacturing, commercial, regulatory, and technical nature issues for field applicability more likely have hindered their wider entrance into veterinary medicine and practice than have fundamental science gaps. This chapter begins by outlining the current situation, requirements, difficulties, and perspectives of point-of-care tests for diagnosing diseases of veterinary interest. Nucleic-acid testing, particularly for the point of care, is addressed subsequently. A range of valuable signal transduction mechanisms commonly employed in proof-of-concept schemes and techniques born on the analytical chemistry laboratories are also described. As the essential core of this chapter, sections dedicated to the principles and applications of microfluidics, lab-on-a-chip, and nanotechnology for the development of point-of-care tests are presented. Microdevices already applied or under development for application in field diagnosis of animal diseases are reviewed.

Citing Articles

Point-of-Care Diagnostics for Farm Animal Diseases: From Biosensors to Integrated Lab-on-Chip Devices.

Manessis G, Gelasakis A, Bossis I Biosensors (Basel). 2022; 12(7).

PMID: 35884258 PMC: 9312888. DOI: 10.3390/bios12070455.


Effect of green GO/Au nanocomposite on in-vitro amplification of human DNA.

Maleki M, Ghasemi Y, Pourhassan-Moghaddam M, Asadi N, Dadashpour M, Mohammadi S IET Nanobiotechnol. 2019; 13(9):887-890.

PMID: 31811755 PMC: 8676293. DOI: 10.1049/iet-nbt.2018.5082.


Hypereosinophilic Syndrome Complicated by Eosinophilic Myocarditis With Dramatic Response to Steroid.

Khalid M, Gayam V, Dahal S, Rahman E, Fadllala K, Kaler J J Investig Med High Impact Case Rep. 2018; 6:2324709618764512.

PMID: 29581993 PMC: 5862364. DOI: 10.1177/2324709618764512.


Chagas Disease Diagnostic Applications: Present Knowledge and Future Steps.

Balouz V, Aguero F, Buscaglia C Adv Parasitol. 2017; 97:1-45.

PMID: 28325368 PMC: 5363286. DOI: 10.1016/bs.apar.2016.10.001.


Integrated Microfluidic Nucleic Acid Isolation, Isothermal Amplification, and Amplicon Quantification.

Mauk M, Liu C, Song J, Bau H Microarrays (Basel). 2016; 4(4):474-89.

PMID: 27600235 PMC: 4996405. DOI: 10.3390/microarrays4040474.


References
1.
Pipper J, Inoue M, Ng L, Neuzil P, Zhang Y, Novak L . Catching bird flu in a droplet. Nat Med. 2007; 13(10):1259-63. PMC: 7095864. DOI: 10.1038/nm1634. View

2.
Aguilera-Herrador E, Cruz-Vera M, Valcarcel M . Analytical connotations of point-of-care testing. Analyst. 2010; 135(9):2220-32. DOI: 10.1039/c0an00307g. View

3.
Gialamas A, Laurence C, Yelland L, Tideman P, Worley P, Shephard M . Assessing agreement between point of care and laboratory results for lipid testing from a clinical perspective. Clin Biochem. 2009; 43(4-5):515-8. DOI: 10.1016/j.clinbiochem.2009.11.014. View

4.
Spain E, Keyes T, Forster R . DNA sensor based on vapour polymerised pedot films functionalised with gold nanoparticles. Biosens Bioelectron. 2012; 41:65-70. DOI: 10.1016/j.bios.2012.06.046. View

5.
Madi M, Hamilton A, Squirrell D, Mioulet V, Evans P, Lee M . Rapid detection of foot-and-mouth disease virus using a field-portable nucleic acid extraction and real-time PCR amplification platform. Vet J. 2011; 193(1):67-72. DOI: 10.1016/j.tvjl.2011.10.017. View