» Articles » PMID: 25255945

3D GABA Imaging with Real-time Motion Correction, Shim Update and Reacquisition of Adiabatic Spiral MRSI

Overview
Journal Neuroimage
Specialty Radiology
Date 2014 Sep 27
PMID 25255945
Citations 67
Authors
Affiliations
Soon will be listed here.
Abstract

Gamma-aminobutyric acid (GABA) and glutamate (Glu) are the major neurotransmitters in the brain. They are crucial for the functioning of healthy brain and their alteration is a major mechanism in the pathophysiology of many neuro-psychiatric disorders. Magnetic resonance spectroscopy (MRS) is the only way to measure GABA and Glu non-invasively in vivo. GABA detection is particularly challenging and requires special MRS techniques. The most popular is MEscher-GArwood (MEGA) difference editing with single-voxel Point RESolved Spectroscopy (PRESS) localization. This technique has three major limitations: a) MEGA editing is a subtraction technique, hence is very sensitive to scanner instabilities and motion artifacts. b) PRESS is prone to localization errors at high fields (≥3T) that compromise accurate quantification. c) Single-voxel spectroscopy can (similar to a biopsy) only probe steady GABA and Glu levels in a single location at a time. To mitigate these problems, we implemented a 3D MEGA-editing MRS imaging sequence with the following three features: a) Real-time motion correction, dynamic shim updates, and selective reacquisition to eliminate subtraction artifacts due to scanner instabilities and subject motion. b) Localization by Adiabatic SElective Refocusing (LASER) to improve the localization accuracy and signal-to-noise ratio. c) K-space encoding via a weighted stack of spirals provides 3D metabolic mapping with flexible scan times. Simulations, phantom and in vivo experiments prove that our MEGA-LASER sequence enables 3D mapping of GABA+ and Glx (Glutamate+Gluatmine), by providing 1.66 times larger signal for the 3.02ppm multiplet of GABA+ compared to MEGA-PRESS, leading to clinically feasible scan times for 3D brain imaging. Hence, our sequence allows accurate and robust 3D-mapping of brain GABA+ and Glx levels to be performed at clinical 3T MR scanners for use in neuroscience and clinical applications.

Citing Articles

ECCENTRIC: A fast and unrestrained approach for high-resolution in vivo metabolic imaging at ultra-high field MR.

Klauser A, Strasser B, Bogner W, Hingerl L, Courvoisier S, Schirda C Imaging Neurosci (Camb). 2024; 2:1-20.

PMID: 39679200 PMC: 11638761. DOI: 10.1162/imag_a_00313.


Proton-free induction decay MRSI at 7 T in the human brain using an egg-shaped modified rosette K-space trajectory.

Blomer S, Hingerl L, Marjanska M, Bogner W, Motyka S, Hangel G Magn Reson Med. 2024; 93(4):1443-1457.

PMID: 39568225 PMC: 11782714. DOI: 10.1002/mrm.30368.


High-quality lipid suppression and B0 shimming for human brain H MRSI.

Kumaragamage C, McIntyre S, Nixon T, De Feyter H, de Graaf R Neuroimage. 2024; 300:120845.

PMID: 39276817 PMC: 11540284. DOI: 10.1016/j.neuroimage.2024.120845.


Enhancing Whole-Brain Magnetic Field Homogeneity for 3D-Magnetic Resonance Spectroscopic Imaging with a Novel Unified Coil: A Preliminary Study.

Malagi A, Li X, Zhang N, Liu Y, Huang Y, Serry F Cancers (Basel). 2024; 16(6).

PMID: 38539565 PMC: 10969602. DOI: 10.3390/cancers16061233.


Multi-Parametric Molecular Imaging of the Brain Using Optimized Multi-TE Subspace MRSI.

Wang Z, Li Y, Cao C, Anderson A, Huesmann G, Lam F IEEE Trans Biomed Eng. 2024; 71(6):1732-1744.

PMID: 38170654 PMC: 11160977. DOI: 10.1109/TBME.2023.3349375.


References
1.
Baslow M, Guilfoyle D . Using proton magnetic resonance imaging and spectroscopy to understand brain "activation". Brain Lang. 2006; 102(2):153-64. DOI: 10.1016/j.bandl.2006.06.119. View

2.
Jensen J, Frederick B, Renshaw P . Grey and white matter GABA level differences in the human brain using two-dimensional, J-resolved spectroscopic imaging. NMR Biomed. 2005; 18(8):570-6. DOI: 10.1002/nbm.994. View

3.
Andronesi O, Ramadan S, Mountford C, Sorensen A . Low-power adiabatic sequences for in vivo localized two-dimensional chemical shift correlated MR spectroscopy. Magn Reson Med. 2010; 64(6):1542-56. PMC: 3214589. DOI: 10.1002/mrm.22535. View

4.
Puts N, Edden R . In vivo magnetic resonance spectroscopy of GABA: a methodological review. Prog Nucl Magn Reson Spectrosc. 2012; 60:29-41. PMC: 3383792. DOI: 10.1016/j.pnmrs.2011.06.001. View

5.
Posse S, Tedeschi G, Risinger R, Ogg R, Le Bihan D . High speed 1H spectroscopic imaging in human brain by echo planar spatial-spectral encoding. Magn Reson Med. 1995; 33(1):34-40. DOI: 10.1002/mrm.1910330106. View