High-quality Lipid Suppression and B0 Shimming for Human Brain H MRSI

Overview
Journal Neuroimage
Specialty Radiology
Date 2024 Sep 14
PMID 39276817
Authors
Affiliations
Soon will be listed here.
Abstract

Magnetic Resonance Spectroscopic Imaging (MRSI) is a powerful technique that can map the metabolic profile in the brain non-invasively. Extracranial lipid contamination and insufficient B homogeneity however hampers robustness, and as a result has hindered widespread use of MRSI in clinical and research settings. Over the last six years we have developed highly effective extracranial lipid suppression methods with a second order gradient insert (ECLIPSE) utilizing inner volume selection (IVS) and outer volume suppression (OVS) methods. While ECLIPSE provides > 100-fold in lipid suppression with modest radio frequency (RF) power requirements and immunity to B field variations, axial coverage is reduced for non-elliptical head shapes. In this work we detail the design, construction, and utility of MC-ECLIPSE, a pulsed second order gradient coil with Z2 and X2Y2 fields, combined with a 54-channel multi-coil (MC) array. The MC-ECLIPSE platform allows arbitrary region of interest (ROI) shaped OVS for full-axial slice coverage, in addition to MC-based B field shimming, for robust human brain proton MRSI. In vivo experiments demonstrate that MC-ECLIPSE allows axial brain coverage of 92-95 % is achieved following arbitrary ROI shaped OVS for various head shapes. The standard deviation (SD) of the residual B field following SH2 and MC shimming were 25 ± 9 Hz and 18 ± 8 Hz over a 5 cm slab, and 18 ± 5 Hz and 14 ± 6 Hz over a 1.5 cm slab, respectively. These results demonstrate that B magnetic field shimming with the MC array supersedes second order harmonic capabilities available on standard MRI systems for both restricted and large ROIs. Furthermore, MC based B shimming provides comparable shimming performance to an unrestricted SH5 shim set for both restricted, and 5-cm slab shim challenges. Phantom experiments demonstrate the high level of localization performance achievable with MC-ECLIPSE, with ROI edge chemical shift displacements ranging from 1-3 mm with a median value of 2 mm, and transition width metrics ranging from 1-2.5 mm throughout the ROI edge. Furthermore, MC based B shimming is comparable to performance following a full set of unrestricted spherical harmonic fields up to order 5. Short echo time MRSI and GABA-edited MRSI acquisitions in the human brain following MC-shimming and arbitrary ROI shaping demonstrate full-axial slice coverage and extracranial lipid artifact free spectra. MC-ECLIPSE allows full-axial coverage and robust MRSI acquisitions, while allowing interrogation of cortical tissue proximal to the skull, which has significant value in a wide range of neurological and psychiatric conditions.

Citing Articles

Rosette Spectroscopic Imaging for Whole-Brain Slab Metabolite Mapping at 7T: Acceleration Potential and Reproducibility.

Huang Z, Emir U, Doring A, Klauser A, Xiao Y, Widmaier M Hum Brain Mapp. 2025; 46(4):e70176.

PMID: 40056040 PMC: 11889463. DOI: 10.1002/hbm.70176.

References
1.
Povazan M, Hangel G, Strasser B, Gruber S, Chmelik M, Trattnig S . Mapping of brain macromolecules and their use for spectral processing of (1)H-MRSI data with an ultra-short acquisition delay at 7 T. Neuroimage. 2015; 121:126-35. DOI: 10.1016/j.neuroimage.2015.07.042. View

2.
Ma R, Murdoch J, Bogner W, Andronesi O, Dydak U . Atlas-based GABA mapping with 3D MEGA-MRSI: Cross-correlation to single-voxel MRS. NMR Biomed. 2020; 34(5):e4275. PMC: 7438238. DOI: 10.1002/nbm.4275. View

3.
Malagi A, Li X, Zhang N, Liu Y, Huang Y, Serry F . Enhancing Whole-Brain Magnetic Field Homogeneity for 3D-Magnetic Resonance Spectroscopic Imaging with a Novel Unified Coil: A Preliminary Study. Cancers (Basel). 2024; 16(6). PMC: 10969602. DOI: 10.3390/cancers16061233. View

4.
Tannus A, Garwood M . Adiabatic pulses. NMR Biomed. 1998; 10(8):423-34. DOI: 10.1002/(sici)1099-1492(199712)10:8<423::aid-nbm488>3.0.co;2-x. View

5.
Pan J, Duckrow R, Gerrard J, Ong C, Hirsch L, Resor Jr S . 7T MR spectroscopic imaging in the localization of surgical epilepsy. Epilepsia. 2013; 54(9):1668-78. PMC: 3938332. DOI: 10.1111/epi.12322. View