Comparison of Cerebral Blood Flow Acquired by Simultaneous [15O]water Positron Emission Tomography and Arterial Spin Labeling Magnetic Resonance Imaging

Abstract

Until recently, no direct comparison between [(15)O]water positron emission tomography (PET) and arterial spin labeling (ASL) for measuring cerebral blood flow (CBF) was possible. With the introduction of integrated, hybrid magnetic resonance (MR)-PET scanners, such a comparison becomes feasible. This study presents results of CBF measurements recorded simultaneously with [(15)O]water and ASL. A 3T MR-BrainPET scanner was used for the simultaneous acquisition of pseudo-continuous ASL (pCASL) magnetic resonance imaging (MRI) and [(15)O]water PET. Quantitative CBF values were compared in 10 young healthy male volunteers at baseline conditions. A statistically significant (P<0.05) correlation was observed between the two modalities; the whole-brain CBF values determined with PET and pCASL were 43.3±6.1 mL and 51.9±7.1 mL per 100 g per minute, respectively. The gray/white matter (GM/WM) ratio of CBF was 3.0 for PET and 3.4 for pCASL. A paired t-test revealed differences in regional CBF between ASL and PET with higher ASL-CBF than PET-CBF values in cortical areas. Using an integrated, hybrid MR-PET a direct simultaneous comparison between ASL and [(15)O]water PET became possible for the first time so that temporal, physiologic, and functional variations were avoided. Regional and individual differences were found despite the overall similarity between ASL and PET, requiring further detailed investigations.

Citing Articles

Blood biomarkers for vascular cognitive impairment based on neuronal function: a systematic review and meta-analysis.

Huang W, Liao L, Liu Q, Ma R, He X, Du X Front Neurol. 2025; 16:1496711.

PMID: 39990267 PMC: 11842260. DOI: 10.3389/fneur.2025.1496711.


Compartmental modeling for blood flow quantification from dynamic O-water PET images of humans: a systematic review.

Rainio O, Klen R Ann Nucl Med. 2025; 39(3):231-246.

PMID: 39832118 PMC: 11829939. DOI: 10.1007/s12149-025-02014-x.


Ex Vivo Simultaneous HO Positron Emission Tomography and Magnetic Resonance Imaging of Porcine Kidneys-A Feasibility Study.

Arildsen M, Mariager C, Overgaard C, Vorre T, Bojesen M, Moeslund N J Imaging. 2024; 10(9).

PMID: 39330429 PMC: 11433579. DOI: 10.3390/jimaging10090209.


Real-time motion-enabling positron emission tomography of the brain of upright ambulatory humans.

Siva N, Bauer C, Glover C, Stolin A, Chandi S, Melnick H Commun Med (Lond). 2024; 4(1):117.

PMID: 38872007 PMC: 11176317. DOI: 10.1038/s43856-024-00547-2.


Recommendations for quantitative cerebral perfusion MRI using multi-timepoint arterial spin labeling: Acquisition, quantification, and clinical applications.

Woods J, Achten E, Asllani I, Bolar D, Dai W, Detre J Magn Reson Med. 2024; 92(2):469-495.

PMID: 38594906 PMC: 11142882. DOI: 10.1002/mrm.30091.


References
1.
Cameron O, Modell J, Hariharan M . Caffeine and human cerebral blood flow: a positron emission tomography study. Life Sci. 1990; 47(13):1141-6. DOI: 10.1016/0024-3205(90)90174-p. View

2.
Herzog H, Seitz R, Tellmann L, Kops E, Julicher F, Schlaug G . Quantitation of regional cerebral blood flow with 15O-butanol and positron emission tomography in humans. J Cereb Blood Flow Metab. 1996; 16(4):645-9. DOI: 10.1097/00004647-199607000-00015. View

3.
Bokkers R, Bremmer J, van Berckel B, Lammertsma A, Hendrikse J, Pluim J . Arterial spin labeling perfusion MRI at multiple delay times: a correlative study with H(2)(15)O positron emission tomography in patients with symptomatic carotid artery occlusion. J Cereb Blood Flow Metab. 2009; 30(1):222-9. PMC: 2949108. DOI: 10.1038/jcbfm.2009.204. View

4.
van Osch M, Teeuwisse W, van Walderveen M, Hendrikse J, Kies D, van Buchem M . Can arterial spin labeling detect white matter perfusion signal?. Magn Reson Med. 2009; 62(1):165-73. DOI: 10.1002/mrm.22002. View

5.
Xu G, Rowley H, Wu G, Alsop D, Shankaranarayanan A, Dowling M . Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease. NMR Biomed. 2009; 23(3):286-93. PMC: 2843795. DOI: 10.1002/nbm.1462. View