» Articles » PMID: 24608066

A Motion-tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors

Overview
Date 2014 Mar 11
PMID 24608066
Citations 43
Authors
Affiliations
Soon will be listed here.
Abstract

The performance of portable and wearable biosensors is highly influenced by motion artifact. In this paper, a novel real-time adaptive algorithm is proposed for accurate motion-tolerant extraction of heart rate (HR) and pulse oximeter oxygen saturation ( SpO2) from wearable photoplethysmographic (PPG) biosensors. The proposed algorithm removes motion artifact due to various sources including tissue effect and venous blood changes during body movements and provides noise-free PPG waveforms for further feature extraction. A two-stage normalized least mean square adaptive noise canceler is designed and validated using a novel synthetic reference signal at each stage. Evaluation of the proposed algorithm is done by Bland-Altman agreement and correlation analyses against reference HR from commercial ECG and SpO2 sensors during standing, walking, and running at different conditions for a single- and multisubject scenarios. Experimental results indicate high agreement and high correlation (more than 0.98 for HR and 0.7 for SpO2 extraction) between measurements by reference sensors and our algorithm.

Citing Articles

MultiPhys: Heterogeneous Fusion of Mamba and Transformer for Video-Based Multi-Task Physiological Measurement.

Huo C, Yin P, Fu B Sensors (Basel). 2025; 25(1.

PMID: 39796891 PMC: 11722562. DOI: 10.3390/s25010100.


A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring.

Jhuma F, Harada K, Misran M, Mo H, Fujimoto H, Hattori R Sensors (Basel). 2024; 24(23).

PMID: 39686169 PMC: 11644845. DOI: 10.3390/s24237634.


Advances in Wearable Biosensors for Healthcare: Current Trends, Applications, and Future Perspectives.

Vo D, Trinh K Biosensors (Basel). 2024; 14(11).

PMID: 39590019 PMC: 11592256. DOI: 10.3390/bios14110560.


Recent advances in wearable sensors and data analytics for continuous monitoring and analysis of biomarkers and symptoms related to COVID-19.

Li H, Yuan J, Fennell G, Abdulla V, Nistala R, Dandachi D Biophys Rev (Melville). 2024; 4(3):031302.

PMID: 38510705 PMC: 10903389. DOI: 10.1063/5.0140900.


Pulse Oximetry Based on Quadrature Multiplexing of the Amplitude Modulated Photoplethysmographic Signals.

Koseeyaporn J, Wardkein P, Sinchai A, Kainan P, Tuwanut P Sensors (Basel). 2023; 23(13).

PMID: 37447955 PMC: 10346872. DOI: 10.3390/s23136106.