Abstract

Commercial off-the shelf (COTS) wearable devices continue development at unprecedented rates. An unfortunate consequence of their rapid commercialization is the lack of independent, third-party accuracy verification for reported physiological metrics of interest, such as heart rate (HR) and heart rate variability (HRV). To address these shortcomings, the present study examined the accuracy of seven COTS devices in assessing resting-state HR and root mean square of successive differences (rMSSD). Five healthy young adults generated 148 total trials, each of which compared COTS devices against a validation standard, multi-lead electrocardiogram (mECG). All devices accurately reported mean HR, according to absolute percent error summary statistics, although the highest mean absolute percent error (MAPE) was observed for CameraHRV (17.26%). The next highest MAPE for HR was nearly 15% less (HRV4Training, 2.34%). When measuring rMSSD, MAPE was again the highest for CameraHRV [112.36%, concordance correlation coefficient (CCC): 0.04], while the lowest MAPEs observed were from HRV4Training (4.10%; CCC: 0.98) and OURA (6.84%; CCC: 0.91). Our findings support extant literature that exposes varying degrees of veracity among COTS devices. To thoroughly address questionable claims from manufacturers, elucidate the accuracy of data parameters, and maximize the real-world applicative value of emerging devices, future research must continually evaluate COTS devices.

Citing Articles

Deriving Accurate Nocturnal Heart Rate, rMSSD and Frequency HRV from the Oura Ring.

Liang T, Yilmaz G, Soon C Sensors (Basel). 2024; 24(23).

PMID: 39686012 PMC: 11644394. DOI: 10.3390/s24237475.


Cancer and Stress: Understanding the Connections and Interventions.

DAndre S, Ellsworth L, Kirsch J, Montane H, Kruger M, Donovan K Am J Lifestyle Med. 2024; :15598276241304373.

PMID: 39651486 PMC: 11624519. DOI: 10.1177/15598276241304373.


A Bayesian analysis of heart rate variability changes over acute episodes of bipolar disorder.

Corponi F, Li B, Anmella G, Valenzuela-Pascual C, Pacchiarotti I, Valenti M Npj Ment Health Res. 2024; 3(1):44.

PMID: 39363115 PMC: 11449927. DOI: 10.1038/s44184-024-00090-x.


The Effect of In-Ear and Behind-Ear Transcutaneous Auricular Vagus Nerve Stimulation on Autonomic Function: A Randomized, Single-Blind, Sham-Controlled Study.

Percin A, Ozden A, Yenisehir S, Pehlivanoglu B, Yilmaz R J Clin Med. 2024; 13(15).

PMID: 39124651 PMC: 11312612. DOI: 10.3390/jcm13154385.


Digital biomarkers for non-motor symptoms in Parkinson's disease: the state of the art.

Janssen Daalen J, van den Bergh R, Prins E, Sadat Chenarani Moghadam M, van den Heuvel R, Veen J NPJ Digit Med. 2024; 7(1):186.

PMID: 38992186 PMC: 11239921. DOI: 10.1038/s41746-024-01144-2.


References
1.
Achten J, Jeukendrup A . Heart rate monitoring: applications and limitations. Sports Med. 2003; 33(7):517-38. DOI: 10.2165/00007256-200333070-00004. View

2.
Massin M, Derkenne B, von Bernuth G . Correlations between indices of heart rate variability in healthy children and children with congenital heart disease. Cardiology. 1999; 91(2):109-13. DOI: 10.1159/000006889. View

3.
Muller A, Wang N, Yao J, Tan C, Low I, Lim N . Heart Rate Measures From Wrist-Worn Activity Trackers in a Laboratory and Free-Living Setting: Validation Study. JMIR Mhealth Uhealth. 2019; 7(10):e14120. PMC: 6777285. DOI: 10.2196/14120. View

4.
Nakano N, Sakura T, Ueda K, Omura L, Kimura A, Iino Y . Evaluation of 3D Markerless Motion Capture Accuracy Using OpenPose With Multiple Video Cameras. Front Sports Act Living. 2020; 2:50. PMC: 7739760. DOI: 10.3389/fspor.2020.00050. View

5.
Depner C, Cheng P, Devine J, Khosla S, de Zambotti M, Robillard R . Wearable technologies for developing sleep and circadian biomarkers: a summary of workshop discussions. Sleep. 2019; 43(2). PMC: 7368340. DOI: 10.1093/sleep/zsz254. View