» Articles » PMID: 24158470

Attenuation of Systolic Blood Pressure and Pulse Transit Time Hysteresis During Exercise and Recovery in Cardiovascular Patients

Overview
Date 2013 Oct 26
PMID 24158470
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Pulse transit time (PTT) is a cardiovascular parameter of emerging interest due to its potential to estimate blood pressure (BP) continuously and without a cuff. Both linear and nonlinear equations have been used in the estimation of BP based on PTT. This study, however, demonstrates that there is a hysteresis phenomenon between BP and PTT during and after dynamic exercise. A total of 46 subjects including 16 healthy subjects, 13 subjects with one or more cardiovascular risk factors, and 17 patients with cardiovascular disease underwent graded exercise stress test. PTT was measured from electrocardiogram and photoplethysmogram of the left index finger of the subject, i.e., a pathway that includes predominately aorta, brachial, and radial arteries. The results of this study showed that, for the same systolic BP (SBP), PTT measured during exercise was significantly larger than PTT measured during recovery for all subject groups. This hysteresis was further quantified as both normalized area bounded by the SBP-PTT relationship (AreaN) and SBP difference at PTT during peak exercise plus 20 ms (ΔSBP20). Significant attenuation of both AreaN (p <; 0.05) and ΔSBP20 (p <; 0.01) is observed in cardiovascular patients compared with healthy subjects, independent of resting BP. Since the SBP-PTT relationship are determined by the mechanical properties of arterial wall, which is predominately mediated by the sympathetic nervous system through altered vascular smooth muscle (VSM) tone during exercise, results of this study are consistent with the previous findings of autonomic nervous dysfunction in cardiovascular patients. We further conclude that VSM tone has a nonnegligible influence on the BP-PTT relationship and thus should be considered in the PTT-based BP estimation.

Citing Articles

History and evolution of blood pressure measurement.

Noh S, Kim H, Kang S, Yoon C, Youn T, Chae I Clin Hypertens. 2024; 30(1):9.

PMID: 38556854 PMC: 10983645. DOI: 10.1186/s40885-024-00268-7.


Estimating Blood Pressure during Exercise with a Cuffless Sphygmomanometer.

Hayashi K, Maeda Y, Yoshimura T, Huang M, Tamura T Sensors (Basel). 2023; 23(17).

PMID: 37687854 PMC: 10490341. DOI: 10.3390/s23177399.


Wrist ballistocardiography and invasively recorded blood pressure in healthy volunteers during reclining bike exercise.

Steffensen T, Schjerven F, Flade H, Kirkeby-Garstad I, Ingestrom E, Solberg F Front Physiol. 2023; 14:1189732.

PMID: 37250120 PMC: 10213206. DOI: 10.3389/fphys.2023.1189732.


Challenges Presented by Cuffless Measurement of Blood Pressure if Adopted for Diagnosis and Treatment of Hypertension.

Avolio A, Cox J, Louka K, Shirbani F, Tan I, Qasem A Pulse (Basel). 2023; 10(1-4):34-45.

PMID: 36660438 PMC: 9843645. DOI: 10.1159/000522660.


Cuffless Blood Pressure Monitoring: Academic Insights and Perspectives Analysis.

Li S, Zhang C, Xu Z, Liang L, Tian Y, Li L Micromachines (Basel). 2022; 13(8).

PMID: 36014147 PMC: 9415520. DOI: 10.3390/mi13081225.