» Articles » PMID: 24049561

Marginal Fit of Anterior 3-unit Fixed Partial Zirconia Restorations Using Different CAD/CAM Systems

Overview
Specialty Dentistry
Date 2013 Sep 20
PMID 24049561
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs.

Materials And Methods: Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test.

Results: Mean marginal gaps of 3-unit FPDs were 60.46 µm for the Everest group, 78.71 µm for the Lava group, and 81.32 µm for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05).

Conclusion: The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

Citing Articles

Marginal adaptation of different monolithic zirconia crowns with horizontal and vertical finish lines: A comparative in vitro study.

Nasir M, Kadhim A J Dent Res Dent Clin Dent Prospects. 2024; 17(4):235-241.

PMID: 38584994 PMC: 10998165. DOI: 10.34172/joddd.2023.40589.


SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials.

Ferrini F, Paolone G, Di Domenico G, Pagani N, Gherlone E Materials (Basel). 2023; 16(6).

PMID: 36984293 PMC: 10058296. DOI: 10.3390/ma16062413.


Three-dimensional assessment of internal adaptation measurement of three cad/cam ceramic systems.

Elsharkawy E, ElKouedi A, Shokry T Braz Dent J. 2022; 33(6):121-128.

PMID: 36477959 PMC: 9733377. DOI: 10.1590/0103-6440202204981.


Fully Digital versus Conventional Workflows for Fabricating Posterior Three-Unit Implant-Supported Reconstructions: A Prospective Crossover Clinical Trial.

Hashemi A, Hashemi H, Siadat H, Shamshiri A, Afrashtehfar K, Alikhasi M Int J Environ Res Public Health. 2022; 19(18).

PMID: 36141729 PMC: 9517085. DOI: 10.3390/ijerph191811456.


How adjustment could affect internal and marginal adaptation of CAD/CAM crowns made with different materials.

Hasanzade M, Moharrami M, Alikhasi M J Adv Prosthodont. 2021; 12(6):344-350.

PMID: 33489018 PMC: 7790605. DOI: 10.4047/jap.2020.12.6.344.


References
1.
Bindl A, Mormann W . Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent. 2007; 27(6):567-75. View

2.
Okutan M, Heydecke G, Butz F, Strub J . Fracture load and marginal fit of shrinkage-free ZrSiO4 all-ceramic crowns after chewing simulation. J Oral Rehabil. 2006; 33(11):827-32. DOI: 10.1111/j.1365-2842.2006.01637.x. View

3.
Belles D, Cronin Jr R, Duke E . Effect of metal design and technique on the marginal characteristics of the collarless metal ceramic restoration. J Prosthet Dent. 1991; 65(5):611-9. DOI: 10.1016/0022-3913(91)90193-z. View

4.
Beuer F, Schweiger J, Edelhoff D . Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J. 2008; 204(9):505-11. DOI: 10.1038/sj.bdj.2008.350. View

5.
Beuer F, Naumann M, Gernet W, Sorensen J . Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Investig. 2008; 13(3):343-9. DOI: 10.1007/s00784-008-0224-6. View