» Articles » PMID: 15899023

Marginal and Internal Fit of All-ceramic CAD/CAM Crown-copings on Chamfer Preparations

Overview
Journal J Oral Rehabil
Specialty Dentistry
Date 2005 May 19
PMID 15899023
Citations 59
Authors
Affiliations
Soon will be listed here.
Abstract

Evaluation of the marginal and internal fit of all-ceramic molar crown-copings hypothesizing that Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) fabrication shows the same accuracy of fit as conventional techniques. A set of six individual crown preparations was duplicated 12 times yielding 72 plaster dies. Slip-cast (In-Ceram Zirconia), heat-pressing (Empress II) and CAD/CAM crown-copings (Cerec inLab, DCS, Decim and Procera) were seated on 12 dies each. Marginal and internal gap width was measured in the SEM at 120x magnification. Marginal gap of slip-cast (25 +/- 18 microm) was significantly (P < 0.05) smaller than that of Empress II (44 +/- 23 microm) copings. Procera (17 +/- 16 microm) and Decim (23 +/- 17 microm) did not differ (P > 0.05) from slip-cast (25 +/- 18 microm) but were smaller (P < 0.001/P < 0.01) than Empress II (44 +/- 23 microm) and Cerec inLab (43 +/- 23 microm) (P < 0.001/P < 0.05). DCS (33 +/- 20 microm) did not differ (P > 0.05) from any of the others. The internal mid-orobuccal gap width of Procera (136 +/- 68 microm) was larger (P < 0.001) than that of Decim (81 +/- 30 microm) and slip-cast (94 +/- 84 microm) (P < 0.05) while Empress II (105 +/- 53 microm), DCS (110 +/- 79 microm) and Cerec inLab (114 +/- 58 microm) did not differ significantly (P > 0.05) from Decim, Procera and slip-cast. Internal mesiodistal gap width was similar. The fit of conventional and CAD/CAM all-ceramic molar crown-copings covered the same range of gap width confirming the assumed hypothesis.

Citing Articles

Evaluation of the Accuracy of Intraoral Digital Impression Systems and CAD and CAM Workflows for Fabricating Dental Prostheses.

Gajbhiye O, Reddy M, Imran M, Narayanan N, Gangadharappa P, Dewan H J Pharm Bioallied Sci. 2025; 16(Suppl 4):S3734-S3736.

PMID: 39926865 PMC: 11804981. DOI: 10.4103/jpbs.jpbs_1180_24.


Evaluation of Marginal Fit of CAD/CAM Ceramic Crowns and Scanning Time Using Different Intraoral Scanning Systems.

Pereira L, de Melo B, Oliveira A, Mendonca G, Raposo L, Prudente M J Funct Biomater. 2024; 15(12).

PMID: 39728159 PMC: 11677190. DOI: 10.3390/jfb15120359.


An In Vitro Comparison of Marginal Fit of Single-Unit Copings Fabricated Using Computer-Aided Design/Computer-Aided Manufacturing Zirconia, Direct Metal Laser Sintering and Porcelain-Fused-to-Metal.

Kale A, Jain S, Bhasin N, Jaiswal S, Grover R, Singh B Cureus. 2024; 16(10):e71748.

PMID: 39559647 PMC: 11570445. DOI: 10.7759/cureus.71748.


Evaluation of the Marginal Fit of Virgilite Based Lithium Disilicate Ceramic Crowns: An Comparative Study.

Sultan S, Alsabilah K, Alharbi B, Alnaser A J Pharm Bioallied Sci. 2024; 16(Suppl 3):S2479-S2481.

PMID: 39346257 PMC: 11426714. DOI: 10.4103/jpbs.jpbs_330_24.


Clinical Performance of Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) Resin Nanoceramic Endocrowns in Restoring Molars: An In Vivo Study.

Ibrahem S, Morad L, Husein H Cureus. 2024; 16(7):e64252.

PMID: 39131021 PMC: 11315435. DOI: 10.7759/cureus.64252.