» Articles » PMID: 18092451

Fit of All-ceramic Posterior Fixed Partial Denture Frameworks in Vitro

Overview
Specialty Dentistry
Date 2007 Dec 21
PMID 18092451
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

The objective of this study was to evaluate, by scanning electron microscopy, the marginal and internal fit of all-ceramic three-unit fixed partial denture (FPD) frames fabricated by computer-assisted design/computer-aided machining (CAD/CAM) and CAM techniques using blocks of infiltration ceramic, high-strength yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) zirconia sinter ceramic, high-strength dense sintered Y-TZP zirconia ceramic, and glass ceramic. Slip-cast infiltration ceramic was used as a traditional control. The cementation interface widths of the FPD frame copings on butt (A) shoulders of Cerec In-Ceram zirconia (A1, 53 +/- 17 microm) were smaller than those of slip-cast In-Ceram zirconia (A6, 113 +/- 25 microm). Cerec Y-TZP zirconia (A2, 53 +/- 9 pm) and DCS Y-TZP zirconia (A4, 32 +/- 6 microm) interfaces were both significantly smaller than those of Cercon Y-TZP zirconia (A5, 120 +/- 6 microm). Internally, A2 (103 +/- 14) interfaces were smaller than A4 interfaces (144 +/- 15 microm). On chamfer shoulders (B), Cerec Y-TZP zirconia (B1, 71 +/- 5 microm) interfaces were smaller than Cercon interfaces (B2, 129 +/- 38 microm); internally, B1 (80 +/- 11 microm) interfaces were smaller than B2 interfaces (130 +/- 12 microm). CAD/CAM produced better marginal and internal accuracy of fit compared to slip casting and CAM techniques.

Citing Articles

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems.

Bae E, Cho W, Park D, Hwang S, Lee S, Yun M J Adv Prosthodont. 2023; 15(3):155-170.

PMID: 37441720 PMC: 10333096. DOI: 10.4047/jap.2023.15.3.155.


Comparative analysis on intaglio surface trueness, wear volume loss of antagonist, and fracture resistance of full-contour monolithic zirconia crown for single-visit dentistry under simulated mastication.

Kim Y, Yoon H, Kim D, Han J J Adv Prosthodont. 2022; 14(3):173-181.

PMID: 35855321 PMC: 9259349. DOI: 10.4047/jap.2022.14.3.173.


Bacterial translocation and microgap formation at a novel conical indexed implant abutment system for single crowns.

Gehrke P, Burg S, Peters U, Beikler T, Fischer C, Rupp F Clin Oral Investig. 2021; 26(2):1375-1389.

PMID: 34401947 PMC: 8816325. DOI: 10.1007/s00784-021-04112-2.


Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Lehmann K, Weyhrauch M, Bjelopavlovic M, Scheller H, Staedt H, Ottl P Materials (Basel). 2021; 14(10).

PMID: 34069551 PMC: 8161266. DOI: 10.3390/ma14102663.


Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering.

Alikhasi M, Ameri N, Siadat H, Shamshiri A, Nejati M Front Dent. 2019; 16(3):194-205.

PMID: 31858085 PMC: 6911669. DOI: 10.18502/fid.v16i3.1591.