» Articles » PMID: 23993586

Amperometric Biosensor for the Determination of Histamine in Fish Samples

Overview
Journal Food Chem
Date 2013 Sep 3
PMID 23993586
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

A bienzymatic biosensor employing diamine oxidase (DOx) and horseradish peroxidase (HRP) for the detection of histamine in fish samples has been developed and optimized in this work. These enzymes have been co-immobilized into a polysulfone/carbon nanotubes/ferrocene membrane by means of phase inversion technique onto screen-printed electrodes. The electrochemical measurements have been carried out in phosphate buffer solution at pH 8.0 in batch mode and low applied potential (-50 mV vs. Ag/AgCl, KCl 0.1 M) to minimize the interferences. Developed biosensor exhibits high sensitivity (1.9×10(7) nA(-1)), low limit of detection (1.7×10(-7) M), high storage stability and excellent reproducibility, obtaining a linear interval range from 3×10(-7) to 2×10(-5) M. Finally, applicability of the biosensor to the estimation of histamine content in different fish samples has been assessed; obtaining a good correlation between results obtained with the biosensor and those obtained with the reference method (ELISA) in case of sardines, mackerel and greater weever.

Citing Articles

Nanostructured WS@Chitosan-Modified Screen-Printed Carbon Electrodes for Efficient Amperometric Detection of Histamine.

Singh D, Srivastava A, Chaturvedi V, Singh J ACS Omega. 2025; 10(3):3153-3164.

PMID: 39895737 PMC: 11780422. DOI: 10.1021/acsomega.4c10419.


Application of Electrochemical Biosensors for Determination of Food Spoilage.

Majer-Baranyi K, Szekacs A, Adanyi N Biosensors (Basel). 2023; 13(4).

PMID: 37185531 PMC: 10135962. DOI: 10.3390/bios13040456.


Development of cloth-based microfluidic devices for rapid determination of histamine in fish and fishery products.

Senabut J, Praoboon N, Tangkuaram T, Sangsrichan S, Pookmanee P, Kuimalee S Mikrochim Acta. 2023; 190(6):213.

PMID: 37171641 DOI: 10.1007/s00604-023-05792-1.


A Review on Bio- and Chemosensors for the Detection of Biogenic Amines in Food Safety Applications: The Status in 2022.

Givanoudi S, Heyndrickx M, Depuydt T, Khorshid M, Robbens J, Wagner P Sensors (Basel). 2023; 23(2).

PMID: 36679407 PMC: 9860941. DOI: 10.3390/s23020613.


Recent advances in the application of microbial diamine oxidases and other histamine-oxidizing enzymes.

Kettner L, Seitl I, Fischer L World J Microbiol Biotechnol. 2022; 38(12):232.

PMID: 36208352 PMC: 9547800. DOI: 10.1007/s11274-022-03421-2.