» Articles » PMID: 23045362

Non-linear 3D Evaluation of Different Oral Implant-abutment Connections

Overview
Journal J Dent Res
Specialty Dentistry
Date 2012 Oct 10
PMID 23045362
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Micro-gaps and osseous overload in the implant-abutment connection are the most common causes of peri-implant bone resorption and implant failure. These undesirable events can be visualized on standardized three-dimensional finite element models and by radiographic methods. The present study investigated the influence of 7 available implant systems (Ankylos, Astra, Bego, Brånemark, Camlog, Straumann, and Xive) with different implant-abutment connections on bone overload and the appearance of micro-gaps in vitro. The individual geometries of the implants were transferred to three-dimensional finite element models. In a non-linear analysis considering the pre-loading of the occlusion screw, friction between the implant and abutment, the influence of the cone angle on bone strain, and the appearance of micro-gaps were determined. Increased bone strains were correlated with small (< 15°) cone angles. Conical implant-abutment connections efficiently avoided micro-gaps but had a negative effect on peri-implant bone strain. Bone strain was reduced in implants with greater wall thickness (Ankylos) or a smaller cone angle (Bego). The results of our in silico study provide a solid basis for the reduction of peri-implant bone strain and micro-gaps in the implant-abutment connection to improve long-term stability.

Citing Articles

Eleven- to fifteen-year outcome for two-piece implants with an internal tube-in-tube connection: a cross-sectional analysis of 245 implants.

Steyer E, Theisen K, Hulla H, Ubaidha Maheen C, Sokolowski A, Lorenzoni M Oral Maxillofac Surg. 2024; 28(2):859-867.

PMID: 38315402 DOI: 10.1007/s10006-024-01215-4.


Pre-Clinical Models in Implant Dentistry: Past, Present, Future.

Blanc-Sylvestre N, Bouchard P, Chaussain C, Bardet C Biomedicines. 2021; 9(11).

PMID: 34829765 PMC: 8615291. DOI: 10.3390/biomedicines9111538.


Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis.

Matsuoka T, Nakano T, Yamaguchi S, Ono S, Watanabe S, Sato T Materials (Basel). 2021; 14(9).

PMID: 34066506 PMC: 8125587. DOI: 10.3390/ma14092421.


Clinical Performance of Short Expandable Dental Implants for Oral Rehabilitation in Highly Atrophic Alveolar Bone: 3-year Results of a Prospective Single-Center Cohort Study.

Reich W, Schweyen R, Hey J, Otto S, Eckert A Medicina (Kaunas). 2020; 56(7).

PMID: 32635173 PMC: 7404768. DOI: 10.3390/medicina56070333.


A Hybrid Model for Predicting Bone Healing around Dental Implants.

Kung P, Chien S, Tsou N Materials (Basel). 2020; 13(12).

PMID: 32630583 PMC: 7344742. DOI: 10.3390/ma13122858.