» Articles » PMID: 22806510

The Unacknowledged Incidence of Laparoscopic Stapler Malfunction

Overview
Journal Surg Endosc
Publisher Springer
Date 2012 Jul 19
PMID 22806510
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Laparoscopic instruments are being used with increasing frequency. Our surgeons recently experienced several independent adverse events involving the laparoscopic linear stapler. Although the Food and Drug Administration maintains a Manufacturer and User Facility Device Experience (MAUDE) database to track such voluntary reports, many events are not reported and the true incidence of adverse events is unknown. We attempted to determine how frequently minimally invasive surgeons have experienced technical problems with a laparoscopic stapler.

Methods: Following IRB approval, we electronically distributed an anonymous 10-question survey to the 124 minimally invasive program directors listed in the Fellowship Council database. The questions focused on personal or peer experience with laparoscopic stapler malfunction, frequency and type of malfunction, device manufacturer, whether the operation was altered, and root cause analysis of the event.

Results: Forty-four of the 124 program directors (35%) completed the survey. The majority reported personal or peer experience (86%) with a linear stapler not releasing (66%) or not firing (73%) after application, with 27% of the respondents noting that this occurred three or more times. The malfunction was not related to type of load, straight (23%) or reticulating (32%) model, or manufacturer (Ethicon 30%, Covidien 36%). One quarter of the respondents noted that the malfunction caused them to significantly alter their operative procedure, and 30% reported that they received no helpful feedback from the manufacturer despite contacting it.

Conclusions: Most minimally invasive surgeons have experienced laparoscopic linear stapler malfunction and 25% have had to significantly alter the planned operative procedure due to the malfunction.

Citing Articles

Is It Possible to Predict Difficulties During Laparoscopic Sleeve Gastrectomy? A Single Centre Experience.

Pisarska-Adamczyk M, Stefura T, Malczak P, Major P, Wysocki M J Pers Med. 2024; 14(11).

PMID: 39590590 PMC: 11595906. DOI: 10.3390/jpm14111098.


Rare Complications Following Laparoscopic Sleeve Gastrectomy.

Belluzzi A, Sample J, Marrero K, Tomey D, Puvvadi S, Sharma I J Clin Med. 2024; 13(15).

PMID: 39124722 PMC: 11313060. DOI: 10.3390/jcm13154456.


Assessing the Reproducibility of Research Based on the Food and Drug Administration Manufacturer and User Facility Device Experience Data.

Li X, Feng Y, Gong Y, Chen Y J Patient Saf. 2024; 20(5):e45-e58.

PMID: 38470959 PMC: 11636620. DOI: 10.1097/PTS.0000000000001220.


Continuously sutured versus linear-stapled anastomosis in robot-assisted hybrid Ivor Lewis esophageal surgery following neoadjuvant chemoradiotherapy: a single-center cohort study.

Angehrn F, Neuschutz K, Fourie L, Becker P, von Flue M, Steinemann D Surg Endosc. 2022; 36(12):9435-9443.

PMID: 35854126 PMC: 9652283. DOI: 10.1007/s00464-022-09415-3.


Renal pedicle control in laparoscopic donor nephrectomy: Evaluation of a single-center experience.

Fallatah M, Aldughiman A, Binjawhar A, Melaibary B, El-Tholoth H, Al-Gadheeb A Urol Ann. 2022; 14(2):152-155.

PMID: 35711485 PMC: 9197010. DOI: 10.4103/UA.UA_34_20.


References
1.
Champion J, Williams M . Prospective randomized comparison of linear staplers during laparoscopic Roux-en-Y gastric bypass. Obes Surg. 2004; 13(6):855-9. DOI: 10.1381/096089203322618641. View

2.
Brown S, Woo E . Surgical stapler-associated fatalities and adverse events reported to the Food and Drug Administration. J Am Coll Surg. 2004; 199(3):374-81. DOI: 10.1016/j.jamcollsurg.2004.05.264. View

3.
Bard V, Cohen Z, Ross T . An unusual intraoperative complication of stapled colorectal anastomosis: report of a case and review of the literature. Can J Surg. 1993; 36(2):165-8. View