Failure Strength of Human Vertebrae: Prediction Using Bone Mineral Density Measured by DXA and Bone Volume by Micro-CT

Overview
Journal Bone
Date 2012 Mar 21
PMID 22430313
Citations 33
Authors
Affiliations
Soon will be listed here.
Abstract

Significant relationships exist between areal bone mineral density (BMD) derived from dual energy X-ray absorptiometry (DXA) and bone strength. However, the predictive validity of BMD for osteoporotic vertebral fractures remains suboptimal. The diagnostic sensitivity of DXA in the lumbar spine may be improved by assessing BMD from lateral-projection scans, as these might better approximate the objective of measuring the trabecular-rich bone in the vertebral body, compared to the commonly-used posterior-anterior (PA) projections. Nowadays, X-ray micro-computed tomography (μCT) allows non-destructive three-dimensional structural characterization of entire bone segments at high resolution. In this study, human lumbar cadaver spines were examined ex situ by DXA in lateral and PA projections, as well as by μCT, with the aims (1) to investigate the ability of bone quantity measurements obtained by DXA in the lateral projection and in the PA projection, to predict variations in bone quantity measurements obtained by μCT, and (2) to assess their respective capabilities to predict whole vertebral body strength, determined experimentally. Human cadaver spines were scanned by DXA in PA projections and lateral projections. Bone mineral content (BMC) and BMD for L2 and L3 vertebrae were determined. The L2 and L3 vertebrae were then dissected and entirely scanned by μCT. Total bone volume (BV(tot)=cortical+trabecular), trabecular bone volume (BV), and trabecular bone volume fraction (BV/TV) were calculated over the entire vertebrae. The vertebral bodies were then mechanically tested to failure in compression, to determine ultimate load. The variables BV(tot), BV, and BV/TV measured by μCT were better predicted by BMC and BMD measured by lateral-projection DXA, with higher R(2) values and smaller standard errors of the estimate (R(2)=0.65-0.90, SEE=11%-18%), compared to PA-projection DXA (R(2)=0.33-0.53, SEE=22%-34%). The best predictors of ultimate load were BV(tot) and BV assessed by μCT (R(2)=0.88 and R(2)=0.81, respectively), and BMC and BMD from lateral-projection DXA (R(2)=0.82 and R(2)=0.70, respectively). Conversely, BMC and BMD from PA-projection DXA were lower predictors of ultimate load (R(2)=0.49 and R(2)=0.37, respectively). This ex vivo study highlights greater capabilities of lateral-projection DXA to predict variations in vertebral body bone quantity as measured by μCT, and to predict vertebral strength as assessed experimentally, compared to PA-projection DXA. This provides basis for further exploring the clinical application of lateral-projection DXA analysis.

Citing Articles

Evaluation of Cancellous Bone Density from C3 to L5 in 11 Body Donors: CT Versus Micro-CT Measurements.

Schroder G, Akl E, Hillebrand J, Gotz A, Mittlmeier T, Falk S J Clin Med. 2025; 14(4).

PMID: 40004596 PMC: 11856661. DOI: 10.3390/jcm14041059.


Numerical evaluation of spinal reconstruction using a 3D printed vertebral body replacement implant: effects of material anisotropy.

Kang J, Wu Y, Qiao J Front Bioeng Biotechnol. 2024; 12:1305837.

PMID: 38966191 PMC: 11222561. DOI: 10.3389/fbioe.2024.1305837.


Intraoperative lateral wall breach simulation in the cadaveric spine and the impact of thread designs of screws on pullout strength in the osteoporotic thoracic vertebrae: A biomechanical study in human cadavers.

Kaya O, Ozkunt O, Sungur M, Cakir M, Baydogan M, Sariyilmaz K Acta Orthop Traumatol Turc. 2024; 58(1):57-61.

PMID: 38525511 PMC: 11059965. DOI: 10.5152/j.aott.2024.22067.


Visualization of rat tendon in three dimensions using micro-Computed Tomography.

Ditton D, Marchus C, Bozeman A, Martes A, Brumley M, Schiele N MethodsX. 2024; 12:102565.

PMID: 38292310 PMC: 10825692. DOI: 10.1016/j.mex.2024.102565.


A systematic assessment of photon-counting CT for bone mineral density and microarchitecture quantifications.

McCabe C, Sauer T, Zarei M, Segars W, Samei E, Abadi E Proc SPIE Int Soc Opt Eng. 2023; 12463.

PMID: 37125263 PMC: 10142096.