Recent studies have shown that time-resolved optical measurements of the head can estimate changes in the absorption coefficient with depth discrimination. Thus, changes in tissue oxygenation, which are specific to intracranial tissues, can be assessed using this advanced technique, and this method allows us to avoid the influence of changes to extracerebral tissue oxygenation on the measured signals. We report the results of time-resolved optical imaging that was carried out during carotid endarterectomy. This surgery remains the "gold standard" treatment for carotid stenosis, and intraoperative brain oxygenation monitoring may improve the safety of this procedure. A time-resolved optical imager was utilized within the operating theater. This instrument allows for the simultaneous acquisition of 32 distributions of the time-of-flight of photons at two wavelengths on both hemispheres. Analysis of the statistical moments of the measured distributions of the time-of-flight of photons was applied for estimating changes in the absorption coefficient as a function of depth. Time courses of changes in oxy- and deoxyhemoglobin of the extra- and intracerebral compartments during cross-clamping of the carotid arteries were obtained. A decrease in the oxyhemoglobin concentration and an increase in the deoxyhemoglobin concentrations were observed in a large area of the head. Large changes were observed in the hemisphere ipsilateral to the site of clamped carotid arteries. Smaller amplitude changes were noted at the contralateral site. We also found that changes in the hemoglobin signals, as estimated from intracerebral tissue, are very sensitive to clamping of the internal carotid artery, whereas its sensitivity to clamping of the external carotid artery is limited. We concluded that intraoperative multichannel measurements allow for imaging of brain tissue hemodynamics. However, when monitoring the brain during carotid surgery, a single-channel measurement may be sufficient.

Citing Articles

Investigating cortical hypoxia in multiple sclerosis via time-domain near-infrared spectroscopy.

Williams T, Lange F, Smith K, Tachtsidis I, Chataway J Ann Clin Transl Neurol. 2024; 11(9):2372-2381.

PMID: 39037277 PMC: 11537135. DOI: 10.1002/acn3.52150.


Two-layered blood-lipid phantom and method to determine absorption and oxygenation employing changes in moments of DTOFs.

Sudakou A, Wabnitz H, Liemert A, Wolf M, Liebert A Biomed Opt Express. 2023; 14(7):3506-3531.

PMID: 37497481 PMC: 10368065. DOI: 10.1364/BOE.492168.


Multi-laboratory performance assessment of diffuse optics instruments: the BitMap exercise.

Lanka P, Yang L, Orive-Miguel D, Veesa J, Tagliabue S, Sudakou A J Biomed Opt. 2022; 27(7).

PMID: 35701869 PMC: 9199954. DOI: 10.1117/1.JBO.27.7.074716.


Depth-selective data analysis for time-domain fNIRS: moments vs. time windows.

Wabnitz H, Contini D, Spinelli L, Torricelli A, Liebert A Biomed Opt Express. 2020; 11(8):4224-4243.

PMID: 32923038 PMC: 7449728. DOI: 10.1364/BOE.396585.


Depth-resolved assessment of changes in concentration of chromophores using time-resolved near-infrared spectroscopy: estimation of cytochrome-c-oxidase uncertainty by Monte Carlo simulations.

Sudakou A, Wojtkiewicz S, Lange F, Gerega A, Sawosz P, Tachtsidis I Biomed Opt Express. 2019; 10(9):4621-4635.

PMID: 31565513 PMC: 6757481. DOI: 10.1364/BOE.10.004621.