» Articles » PMID: 2230290

Reproducibility of Measurements of Coronary Narrowings by Videodensitometry: Unreliability of Single View Measurements

Overview
Date 1990 Jan 1
PMID 2230290
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Computer-assisted videodensitometry has been shown to be a reliable and reproducible method of measuring absolute and relative coronary narrowings. Using a commercially available analyzer (Vanguard XR70) we confirmed the intra- and interobserver reproducibilities in 34 narrowings in 9 patients. Analyses were performed on normal area and diameter, stenotic area and diameter, percent area stenosis and percent diameter stenosis. For all 6 analyses, excellent intra- and interobserver correlations were found (r = 0.93-0.98), with slopes close to 1 and intercepts close to zero. In a separate study of 16 lesions in 11 patients, each lesion was analyzed in both the RAO and LAO planes. Correlation between the measurements was reasonable with r = 0.76 for the stenotic area and r = 0.75 for the absolute diameter stenosis. However, with suboptimal slopes (0.54 and 0.63 respectively), actual differences between measurements in the two planes were often unacceptably large. These data suggest that videodensitometry is a highly reproducible quantitative angiographic method; however, single view analyses are inadequate for comparative studies.

Citing Articles

The impact of vessel orientation in space on densitometric measurements of cross sectional areas of coronary arteries.

Doriot P, Dorsaz P, Dorsaz L, Chatelain P, RUTISHAUSER W Int J Card Imaging. 1996; 12(4):289-97.

PMID: 8993991 DOI: 10.1007/BF01797742.


Progression and regression of coronary artery disease in one year. Quantitative angiographic assessment in patients with stable angina pectoris.

Balkin J, Zion M, Rosenmann D, Ilan M, Klutstein M, Abraham A Int J Card Imaging. 1993; 9(3):213-7.

PMID: 8106800 DOI: 10.1007/BF01145323.


Morphometry versus densitometry--a comparison by use of casts of human coronary arteries.

Doriot P, Suilen C, Guggenheim N, Dorsaz P, Chappuis F, RUTISHAUSER W Int J Card Imaging. 1992; 8(2):121-30.

PMID: 1629638 DOI: 10.1007/BF01137533.

References
1.
Brown B, Bolson E, Frimer M, DODGE H . Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation. Circulation. 1977; 55(2):329-37. DOI: 10.1161/01.cir.55.2.329. View

2.
Reiber J, Serruys P, Kooijman C, Wijns W, Slager C, Gerbrands J . Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. Circulation. 1985; 71(2):280-8. DOI: 10.1161/01.cir.71.2.280. View

3.
SANMARCO M, Brooks S, Blankenhorn D . Reproducibility of a consensus panel in the interpretation of coronary angiograms. Am Heart J. 1978; 96(4):430-7. DOI: 10.1016/0002-8703(78)90151-5. View

4.
DeRouen T, Murray J, Owen W . Variability in the analysis of coronary arteriograms. Circulation. 1977; 55(2):324-8. DOI: 10.1161/01.cir.55.2.324. View

5.
Nichols A, Gabrieli C, Fenoglio Jr J, Esser P . Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary arteriograms. Circulation. 1984; 69(3):512-22. DOI: 10.1161/01.cir.69.3.512. View