Cinevideodensitometric Analysis of the Effect of Coronary Angioplasty on Coronary Stenotic Dimensions

Overview
Journal Am Heart J
Date 1988 Apr 1
PMID 2965498
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The accuracy and reproducibility of caliper and cinevideodensitometric measurements of coronary stenotic dimensions were compared in radiographic phantom models and in coronary arteriograms of 28 patients undergoing coronary angioplasty. Projected, single-plane coronary cine frames were analyzed by a computer-assisted videodensitometric method, which measures stenotic cross-sectional area without assumptions about lesion geometry. The accuracy (2.4%) and precision (+/- 1.9%) of cinevideodensitometry for measuring percent area stenosis in Plexiglas models of eccentric stenotic lesions was superior to the accuracy (24.7%) and precision (+/- 5.4%) of caliper measurements. Interobserver variability was significantly (p less than 0.05) better for cinevideodensitometric (r = 0.98; SEE = 6.4%) than for caliper measurements (r = 0.87; SEE = 13.1%). After angioplasty, percent diameter stenosis measured by calipers fell from 70 +/- 12% to 30 +/- 15%. Mean percent area reduction measured by cinevideodensitometry fell from 89.1 +/- 8% to 40.1 +/- 22% and stenotic area increased five-fold, from 0.59 +/- 0.5 to 3.47 +/- 1.6 mm2. Pre and post PTCA gradients did not correlate with lesion dimensions. Cinevideodensitometric measurements of absolute stenotic dimensions were more reproducible than relative measurements expressed as a percentage, due to the tapered caliber of normal arterial segments. Thus, cinevideodensitometric measurements were more accurate and reproducible than caliper measurements. The angiographic effects of coronary angioplasty are best measured by cinevideodensitometry, because residual lesions post PTCA are often eccentric, have indistinct margins, and are better characterized by changes in area than by changes in diameter.

Citing Articles

The impact of vessel orientation in space on densitometric measurements of cross sectional areas of coronary arteries.

Doriot P, Dorsaz P, Dorsaz L, Chatelain P, RUTISHAUSER W Int J Card Imaging. 1996; 12(4):289-97.

PMID: 8993991 DOI: 10.1007/BF01797742.


Algorithm effects on computerized vessel analysis from digitized cine film and a new method of generating the centerline of a vessel.

Yanagihara Y, Sugahara T Int J Card Imaging. 1994; 10(1):53-60.

PMID: 8021531 DOI: 10.1007/BF01151581.


A new method for automatic identification of coronary arteries in standard biplane angiograms.

Yanagihara Y, Hashimoto T, Sugahara T, Sugimoto N Int J Card Imaging. 1994; 10(4):253-61.

PMID: 7722346 DOI: 10.1007/BF01137716.


Reproducibility of measurements of coronary narrowings by videodensitometry: unreliability of single view measurements.

Balkin J, Rosenmann D, Ilan M, Zion M Int J Card Imaging. 1990; 5(2-3):119-24.

PMID: 2230290 DOI: 10.1007/BF01833980.


Morphometry versus densitometry--a comparison by use of casts of human coronary arteries.

Doriot P, Suilen C, Guggenheim N, Dorsaz P, Chappuis F, RUTISHAUSER W Int J Card Imaging. 1992; 8(2):121-30.

PMID: 1629638 DOI: 10.1007/BF01137533.